SECTION V:  WATER CONNECTIONS 

 

 

WARNING

 

Failure to install and maintain a new, listed pressure relief valve will release the manufacturer from any 
claim, which might result from excessive temperature and pressures. 
Keep clear of the pressure relief valve discharge line outlet.  The discharge may be hot enough to cause 
scald injury.  The water is under pressure and may splash. 
 

 

WARNING

 

DO NOT reverse the inlet and outlet (cold and hot water) connections on the water heater.  This may 
cause a hazardous operating condition or the water heater may be inoperable 
 

WATER QUALITY 

 

The EVERHOT

 water heater must have the water quality within the following limits for long life and 

reliable operation (see Table 2).  The water supply should be tested to make sure the quality is within the 
specified limits.  If there is a problem with the water quality, contact your local water conditioning company 
for equipment to condition the water supply to this appliance.   

 

NOTICE

 

Operating this water heater with water conditions outside the specified limits will void the warranty. 

 

Table 2 

Description 

pH 

TDS 

(Total 

Dissolved 

Solids) 

Total 

Hardness 

Aluminum Chlorides  Copper 

Iron  Manganese  Zinc 

Levels 

6.5 to 

8.5 

Up to 500 

ppm 

Up to 

200 ppm 

or 11.7 

grains of 

hardness 

Up to 0.2 

ppm 

Up to 

250 ppm 

Up to 

1.0 ppm 

Up to 

0.3 

ppm 

Up to 0.05 

ppm 

Up to 

5 ppm 

 

Lime Condition Warning Signal: 

 

If the EVERHOT water heater is operated under hard water conditions without a water conditioner, the 
error code “LC” may flash on the remote temperature display.  This code means the heat exchanger coil 
is beginning to accumulate scale deposits and MUST be flushed (see Section IX, “Flushing Procedure for 
Lime Scale Removal…”).  Contact your installer for a qualified service technician to flush the heat 
exchanger.  A water conditioner may be needed to prevent this condition from reoccurring.   

 

NOTICE

 

Failure to flush the appliance when “LC” is flashing will cause damage to the heat exchanger.  Damage 
caused by lime or scale build up is not covered by the water heater warranty. 

 

INSTRUCTIONS FOR CONNECTIONS 

 

1.  BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY 

VALVE.

  

After shutting off the main water supply, open a faucet to relieve the water line pressure 

to prevent any water from leaking out of the pipes while making the water connections to the 
water heater.  The COLD water inlet and HOT water outlet are identified on the bottom casing of 
the water heater.  Make the proper plumbing connections between the water heater and the 
plumbing system to the house.  All soldering materials and piping must be compatible with 
potable water.  Unions should be installed on both the hot and cold water lines for future servicing 
and disconnection of the water heater.  Install a shut-off valve in the cold water supply line.   

Содержание Everhot IGE-199C Series

Страница 1: ...hbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or...

Страница 2: ...installed in accordance with local codes In the absence of local codes it must be installed in compliance with the National Fuel Gas Code ANSI Z223 1 Latest Edition or in Canada CAN CGA B149 1 Natural...

Страница 3: ...damage personal injury or loss of life Failure to follow all instructions in the proper order can cause personal injury or death Read and understand all instructions including all those provided with...

Страница 4: ...r heater materials of construction products of combustion and the fuel contain carbon monoxide nitrogen oxides aldehydes and or other toxic or harmful substances which can cause death or serious injur...

Страница 5: ...Input Rating Btu hr Temp Rise 40 F 60 F 80 F 100 F 120 F 140 F IGE 199R 10N IGE 199R 10X IGE 199C 5N IGE 199C 5X 199 000 15 000 Flow Rate Gal Min 7 3 5 9 4 2 3 3 2 8 2 4 First Hour Supply Gal Hr 438...

Страница 6: ...ximum input 0 9 Minimum input Venting System Forced Combustion external vent For Outdoor Installation Only Setpoint Temperature Without remote temperature control 140 F Commercial models 120 F Residen...

Страница 7: ...ds 23 kg and can be installed by 1 person The burners ignite within 3 seconds of water flow 1 2 gallon minute 1 9 L m minimum by direct spark ignition There is no standing pilot A variable speed combu...

Страница 8: ...inish in intensity or fade and not be as readily detectable If you have a diminished sense of smell or are in any way unsure of the presence of gas immediately contact your gas supplier from a telepho...

Страница 9: ...nimum installation clearances before choosing a final location for the water heater 2 The water heater must be installed on a wall capable of supporting at least 50 pounds 23 Kg Locate the water heate...

Страница 10: ...overhangs windows doors etc Also avoid locations where there is heavy water runoff from roofs Determine the proper height and location for the water heater to be installed Consider the water and gas...

Страница 11: ...0 3 ppm Up to 0 05 ppm Up to 5 ppm Lime Condition Warning Signal If the EVERHOT water heater is operated under hard water conditions without a water conditioner the error code LC may flash on the rem...

Страница 12: ...is Debris will clog the mesh strainer of the inlet filter The inlet strainer prevents debris from damaging the flow sensor or clogging the coil It may need to be cleaned periodically and should be cle...

Страница 13: ...13 Recommended Piping for a Basic Installation Fig 2...

Страница 14: ...lowing illustration The drain solenoids are recommended for very cold climates to prevent water heater freeze damage where power failures from ice and windstorms occur The electrical connections for t...

Страница 15: ...15 Recommended Piping for a Circulation System Fig 4...

Страница 16: ...16 Recommended Piping for Back up Storage System For hotels motels and other high flow applications Fig 5 Note The Primary Circulator for the water heating loop must be sized for 21 GPM 35 Ft Head...

Страница 17: ...stall the pressure relief valve into a tee connection from the hot water outlet of the water heater Note Some models may already be equipped or supplied with an installed pressure relief valve Verify...

Страница 18: ...urred such as through improper testing of gas lines or emergency malfunction of the supply system the gas valve must be checked for safe operation Make sure that the outside vents on the supply regula...

Страница 19: ...125 150 175 200 3 6 9 12 15 18 21 24 27 30 38 45 53 61 278 190 152 130 115 105 96 90 84 79 72 64 59 55 1 520 350 285 245 215 195 180 170 160 150 130 120 110 100 1 1050 730 590 500 440 400 370 350 320...

Страница 20: ...around the plugs 7 Replace the front control panel Restore electrical power to the water heater NOTICE If the gas supply pressure is below the specified value check the gas piping to insure that it is...

Страница 21: ...ted by local code then provide a three wire GFI grounding type receptacle within reach of the control box Provide a grounded line cord and connect to the black and white power supply and green ground...

Страница 22: ...22 Wiring Diagram WARNING DO NOT adjust any dipswitch settings on PC board...

Страница 23: ...23 Wiring Diagram Schematic...

Страница 24: ...ature for sanitizing purposes Always check water temperature by hand before entering the shower or bath The temperature may have been changed Test the temperature of the water with your hand or elbow...

Страница 25: ...le for the cable using a 6 4 mm drill bit 3 Run the cable from the control to the water heater or another control which ever is closer or more convenient 4 Remove the face plate from the remote contro...

Страница 26: ...ture setting is 140 F In addition the control will display fault codes in the event the water heater needs service Up to two additional optional remote controls may be purchased and installed if desir...

Страница 27: ...trols with the power on to the water heater There are 120 volt terminals and wiring next to the remote control connections inside the unit All servicing and wiring must be performed by a qualified ins...

Страница 28: ...service professional 1 Flooding to or above the level of the burner or controls 2 External firing 3 Damage 4 Firing without water 5 Sooting NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING CERTAIN I...

Страница 29: ...iately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department OPERATING INSTRUCTIONS 1 STOP Read the safet...

Страница 30: ...water lines A licensed plumbing professional or local plumbing authority should be consulted CAUTION This water heater when set at a lower temperature setting is not capable of producing hot water of...

Страница 31: ...p to 9 error codes if any stored in memory that has been experienced Any error codes will be displayed on the digital monitor in sequence starting with the most recent code 7 To display the water flow...

Страница 32: ...utomatically start heating water whenever a hot water faucet is opened The remote temperature control s will indicate hot water use with the green IN USE indicator 5 All controls can also display diag...

Страница 33: ...child in the bath or shower Do not leave a child or an infirm person in the bath unsupervised This water heater can deliver scalding temperature water at any faucet in the system Be careful whenever...

Страница 34: ...isplayed Fault Remedy 10 Air supply or exhaust blockage Check for a restriction in the exhaust vent 11 No Ignition Check to make sure the gas supply is on to the water heater 12 Flame Failure groundin...

Страница 35: ...3 Check the front vent outlet for any obstructions 4 All electric motors are permanently lubricated and do not need oiling Remove the combustion air blower and clean wheel and housing with soft brush...

Страница 36: ...r out the lime deposits Use the following procedure and diagram fig 13 to flush the heat exchanger and remove the lime scale 1 Disconnect power to the water heater 2 Close valves in the cold water inl...

Страница 37: ...operate the water heater To remedy this situation either increase the total water flow from the tap or using the remote temperature controller decrease the setpoint temperature of the water heater to...

Страница 38: ...38 SCHEMATIC DIAGRAM OF INTERNAL PARTS...

Страница 39: ...39 SECTION X PARTS LIST Cabinet Note Can purchase additional controls for remote locations...

Страница 40: ...40 Internal Components...

Страница 41: ...41 Internal Components...

Страница 42: ...42 Electrical Components...

Страница 43: ...amber Front Plate 1 116 Spark Electrode 1 117 Flame Sense Rod 1 118 Electrode Gasket 1 119 Electrode Holder 1 120 Upper Combustion Chamber Gasket 1 122 Fan Casing Assembly 1 123 Blower Motor 1 127 Blo...

Страница 44: ...Frost Sensing Switch 1 733 120V Anti Frost Heater Assembly 1 734 Sensor Harness 2 1 735 Water Flow Sensor 1 801 Screw 4 802 Washer 4 803 Screw 3 804 Screw 1 805 Screw 3 806 Screw 4 807 Washer 4 808 Sc...

Отзывы: