background image

TROUBLESHOOTING GUIDE 

ELECTRIC INSTANTANEOUS TANKLESS WATER HEATER 

 

 

EFT-5500-4-S-10  

240V 

EFT-7500-4-S-10  

240V 

EFT-9500-4-S-10  

240V 

EFT-8300-4-S-10  

208V 

 

EFT-6000-4-S-10  

277V 

EFT-8000-4-S-10  

277V 

 

EFT-9000-4-S-10  

277V 

 

EFT-10000-4-S-10  

277V 

“THERMOSTATIC”

EFT MODELS

 

 
 

All information necessary to troubleshoot this 

water heating unit is contained in this fully 

illustrated guide. If problems still exist after reading 

and carrying out the instructions in this manual, 

contact Technical Service at the toll free number 

below for assistance 

        

PHONE TOLL FREE 

1-800-334-3393

 

238-43142-00  Rev 3/12/02

 

Содержание EFT-5500-4-S-10

Страница 1: ...EFT 9000 4 S 10 277V EFT 10000 4 S 10 277V THERMOSTATIC EFT MODELS All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exi...

Страница 2: ...dicator light illuminates when the hot water faucet is fully opened If the indicator light illuminates turn to page 5 If the indicator light does not illuminate turn to page 3 If the indicator light f...

Страница 3: ...ific model flow rates Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water faucet record the time In seconds required to fill To c...

Страница 4: ...ods with brass nuts on them Where the wires connect Take a reading of the ohms value between these two rods and write it down See diagram below If the reading is less then 20 ohms on the single Rx1 sc...

Страница 5: ...O Make sure the unit is connected to the voltage supply specified on the U L rating label located on the front cover of the unit STEP THREE Proceed to page four and follow STEP THREE Indicator light i...

Страница 6: ...osition will cause element burn out and may cause further damage to the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on an ES EFC...

Страница 7: ...aucet for 30 seconds and then switch power ON to the unit with the water flowing 0 75 GPM If the light illuminates steadily then call Technical Service and request a replacement printed circuit board...