elecTrical and mechanical TroubleshooTing guide
Condition/Problem
Things to Check
Solution
unit will not power up/turn
on/start
Outlet.
Make sure outlet is functioning correctly.
Verify this
by plugging another object (ex: lamp)
into the outlet. If outlet is connected to a
light switch, check to make sure it is on.
If outlet is not functioning find a working
outlet.
Power cord not plugged in.
Make sure the power cord is firmly
secured to A/C
inlet on the front of the unit and firmly
inserted into a
non-GFI wall socket.
Power switch turned off.
Make sure the power switch at the rear
of the unit is
in the “ON” position.
Safety key not plugged in.
Plug Safety Key into magnetic safety key
location on
display. (See Emergency Stop Procedure
within the Important Safety Precautions
section)
Safety key magnet not
functioning.
Try another magnet if available, such as
refrigerator magnet. If unit works with
different magnet replace safety key.
LED Diagnostic needed.
Access diagnostic LEDs on motor
controller board by following the
instructions in the TC5300/6000
Diagnostics. Caution: Machine is on.
Current is
active!!.
Check the B & G LEDs for the following:
If neither B nor G are lit power is
not reaching the motor controller.
Disconnect unit from power source and
check wiring integrity and connections
between A/C inlet (where cord plugs
in to machine) and motor controller
board. If any visible damage replace A/C
junction kit. If light G is lit but light B is
not lit replace motor controller
I/O Cables
If LEDs B & G are both lit check
connections and for signs of visible
damage to any of the three I/O calbes.
If no visible damage check continuity
using a multi-meter. If a multi-meter is
not available replace all three cables.