background image

3

EN

1.0 - GENERAL INFORMATION

This manual shows you how to safely install, operate and use the device.

The instructions for use 

ALWAYS

 need to be available in the facility where the device is installed.

ATTENTION: installation/maintenance needs to be carried out by qualified staff (as explained in 

section 1.3) by using suitable personal protective equipment (PPE).

For any information pertaining to installation/maintenance or in case of problems that cannot be solved with the instructions, 

contact the manufacturer by using the address and phone numbers provided on the last page.

1.1 - DESCRIPTION

Device which supplies a preset and constant “downstream” pressure value (P2) (within the intended operating limits) when the 

inlet pressure (P1) and/or the flow rate (Q) changes. The compensated obturator ensures precision when adjusting the outlet 

pressure (P2) even in the case of high and sudden variations in the inlet pressure. 

It is fitted with:

•  a spring to adjust the outlet pressure;

•  a safety membrane;
•  output pressure test nipple (with some exceptions) to control the outlet pressure (P2). On some models the pressure 

test nipple is also present on the input;

Reference standards: EN 88-1 – EN 13611.

1.2 - KEY OF SYMBOLS

ATTENTION: 

Attention 

is drawn to the technical 

details intended for 

qualified staff.

DANGER:

  In the event of 

inobservance, this may cause damage 

to tangible goods, to people and/or pets.

DANGER:

 In the event 

of inobservance, this may 

cause damage to tangible 

goods.

1.3 - QUALIFIED STAFF

These are people who:

• Are familiar with product installation, assembly, start-up and maintenance;

• Know the regulations in force in the region or country pertaining to installation and safety;

• Are trained in first aid.

 1.4 - USING NON-ORIGINAL SPARE PARTS

• To perform maintenance or change parts (e.g. spring, filter element, etc.) 

ONLY

 manufacturer-recommended parts can be 

used. Using different parts not only voids the product warranty, it could compromise correct device operation.

• The manufacturer is not liable for malfunctions caused by unauthorised tampering or use of non-original parts.

 1.5 - IMPROPER USE

• The product must only be used for the purpose it was built for. 

• It is not allowed to use fluids other than those expressly stated.

• The technical data set forth on the rating plate must not, under any circumstances, be exceeded. The end user or installer is in 

charge of implementing correct systems to protect the device, which prevent the maximum pressure indicated on the rating plate 

from being exceeded.

• The manufacturer is not responsible for any damage caused by improper use of the device.

Содержание 35501216

Страница 1: ...SSURE REGULATOR 356 P1 max 500 mbar DN15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 DN 80 DN 100 EN EC approval according to EN 88 1 compliant with Regulation EU 2016 426 CE 51CL4012 ED01 MADE IN ITALY II 2G...

Страница 2: ...2 EN INDEX pag English 3 Drawings 10 Dimensions table 1 13 Regulation spring data table 3 14 Diagram 15...

Страница 3: ...2 KEY OF SYMBOLS ATTENTION Attention is drawn to the technical details intended for qualified staff DANGER In the event of inobservance this may cause damage totangiblegoods topeopleand orpets DANGER...

Страница 4: ...downstream of the regulator IMPORTANT install manual gas closing devices e g ball valves upstream and downstream of the regulator to protect it from any pipe leak test If the device is threaded make s...

Страница 5: ...imum torque has been achieved uniformly Common procedures threaded and flanged devices The regulator is normally positioned before the utility Primarily evaluate the possibility of installing the regu...

Страница 6: ...ns provided in this document it does not pose a source of specific hazards in particular under normal operating conditions the regulator emits a flammable substance into the atmosphere ONLY if both th...

Страница 7: ...E Before starting the system make sure that the spring supplied with the regulator is suitable for the desired adjustment pressure The outlet pressure P2 unless specifically requested is factory set w...

Страница 8: ...ary Make sure the sealing O Ring 18 of the bottom cover 16 is inside the relevant groove before putting it back on Reassemble the bottom cover 16 and secure it in its original position being very care...

Страница 9: ...hts of the warranty or compensation for damage The warranty also excludes maintenance work other manufacturers s assembling units making changes to the device and natural wear 8 0 RATING PLATE DATA Th...

Страница 10: ...10 EN fig 1 Threaded connections in line DN 15 DN 20 DN 25...

Страница 11: ...11 EN fig 2 Threaded connections in line DN 32 DN 40 DN 50...

Страница 12: ...12 EN fig 3 Flanged connections DN 65 DN 80 DN 100 19mm...

Страница 13: ...21 Filter element 22 Top disk for membrane 23 Top cover clamping screws 24 Bottom disk for membrane 25 Membrane disc fixing nut 26 Spring washer Table 2 Screw M5 M6 Max torque N m Galvanised 6 10 Sta...

Страница 14: ...3 23 MO 0850 2 2x29x140x18 20 36 MO 0970 2 5x29x155x16 33 58 MO 1000 3 2x29x123x15 5 55 100 MO 1370 3 5x29x125x14 90 190 MO 1070 4x66 5x155x16 DN 65 DN 80 7 18 MO 1100 4 5x70x200x15 5 13 27 MO 1200 5x...

Страница 15: ...15 EN Capacity diagram Diagram calculated with P1 50 mbar and regulator set out of service dv density relative to the air 1 methane 2 air 3 town gas 4 lpg...

Страница 16: ...he right to any technical and construction changes Registered Office Travis Perkins PLC Lodge Way House Lodge Way Harlestone Road Northampton NN5 7UG Telephone Number 0116 245 5500 www bssindustrial c...