Readings on the display
|
89
6 720 643 068 (2011/06)
Copyright (optional information)
15 Readings on the display
The boiler display can provide the following information
(Tab. 35 and 36):
Value displayed
Description
Range
Number or letter, dot
followed by letter
Service function
(
Æ
Tab. 27 / 28, page 66)
Letter followed by
number or letter
Fault code
(
Æ
Tab. 37, page 91) (excep-
tion: b.A = service function)
Three numbers
(
≤
199)
Decimal value, e.g. supply
temperature
00..199
One number (dis-
played for longer) fol-
lowed by two
numbers (displayed
briefly)
Decimal figure (three digits);
first digit is shown alternating
with two last digits
(e.g. 2.69..69 for 269)
0..999
Two dashes followed
by two pairs of num-
bers
Code is shown in three stages:
1. Two dashes 2. First two
digits 3. Last two digits
(e.g. -- 10 04)
1000 ...
9999
Two letters followed
by two pairs of num-
bers
Code is shown in three stages:
1. Two letters 2. First two
digits 3. Last two digits
(e.g. CF 10 20)
Tab. 35 Display readings
Status
code
Description
Acknowledge by pressing any button (except reset).
Acknowledge by pressing two buttons
simultaneously
Acknowledge by pressing and holding for more
than 3 seconds (Save function).
The display shows the supply temperature in alter-
nation with
. The appliance works for 15 minutes
at the minimum nominal output,
Æ
service function
2.F
.
The display shows the supply temperature in alter-
nation with
. The appliance works with the set
maximum output in heating mode,
Æ
service function
1.A
.
The display shows the supply temperature in alter-
nation with
. The appliance works for 15 minutes
at the maximum nominal output,
Æ
service function
2.F
.
The air purging function is active,
Æ
service function
2.C
The display shows the supply temperature in alter-
nation with
. The trap filling sequence is active,
Æ
service function
4.F
.
The display shows the supply temperature alternat-
ing with
: Service reminder,
Æ
service function
5.A
.
The display shows the supply temperature in alter-
nation with
. The pump may have seized,
Æ
fault
E.9
.
The display shows the supply temperature in alter-
nation with
. The temperature gradient limiter
was triggered. Excessive supply temperature
increase: Heating mode is suspended for two min-
utes.
Slab drying function of the FW200 outdoor reset
control (
Æ
operating instructions) or building drying
function (
Æ
service function
7.E
) are activated.
Key pad lock enabled. To unlock the key pad, press
until the supply temperature is shown on the
display.
Tab. 36 Special displays