Establishing the network connection
You can connect the unit to a 10/100 Base-T network using a standard UTP category 5 cable
with RJ45 plugs.
4
Connect the unit to the network via the ETH socket.
Connecting alarm inputs and relay output
Alarm inputs
The unit has 4 alarm inputs on the terminal block. The alarm inputs are used to connect to
external alarm devices such as door contacts or sensors. With the appropriate configuration,
an alarm sensor can automatically connect the unit to a remote location, for example.
A zero potential closing contact or switch can be used as the actuator. If possible, use a
bounce-free contact system as the actuator.
5.3
5.4
VIDEOJET decoder 3000
Connection | en
17
Bosch Sicherheitssysteme GmbH
Installation Manual
2013.08 | V3 | F.01U.281.923