42
en | Cable and Wire Standards
AutoDome Pipe Mount
F.01U.251.410 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
7.
Connect the green (RxD) wire to the C+ pin on the P106
connector.
Figure 3.8
Detail of P106 Connections
8.
Connect the fiber optic cable from the AutoDome to the
LTC 4629.
9.
Close the door to the power supply unit.
10. Ensure that the VG5 AutoDome is set to receive RS232
commands.
–
Remove the bubble from the VG5 AutoDome housing.
–
Locate the protocol switch on the CPU board.
–
Ensure that the protocol switch is in the left position
for RS232 operation.
Figure 3.9
Position of CPU Switch for RS232 Operation
11. Return the bubble to the AutoDome housing.
12. Return power to the power supply box.
1
Green RxD wire connected to C+
2
Blue Ground wire connected to C-
1
Switch Location
2
LEDs
3
Move Switch to the left for RS232 Operation
4
CPU Module
GND TXD RXD
C+ C-
P101
P106
P105
X
F1
02
5
J
J
J103
J1
(LED)
HTR
24V NC 24V
GND
T
XD
R
XD
C+
C-
Содержание VG4-A-9543
Страница 1: ...AutoDome Pipe Mount VG4 A 9543 en Installation Guide ...
Страница 2: ......
Страница 51: ......