AutoDome Pipe Mount
Installing the Pipe Mount | en
27
Bosch Security Systems, Inc.
Installation Guide
F.01U.251.410 | 1.0 | 2011.08
7.
To connect supervised alarms and relays, attach the
appropriate wires to their terminals on the P104 connector
on the Pipe Interface Board (see
Figure 2.7
, above). In
addition, refer to
Section 4 Alarms and Relay Connections,
page 45
for more details on wiring alarms and relays.
Note:
There is a slot located at the top of the Interface
Board to tie the wires to the circuit board with a cable tie.
1
4-pin Alarm
Connector (P102)
2
6-pin Alarm In
Connector (P103)
3
7-pin Relay Connector
(P104)
Pin Description
Pin Description
Pin Description
1
Alarm Out 1
1
Alarm In 3
1
Alarm Out 4 Normally
Open
2
Alarm Out 2
2
Alarm In 4
2
Alarm Out 4 COM
3
Alarm Out 3‡
3
Alarm In 5
3
Alarm Out 4 Normally
Closed
4
Alarm Ground
4
Alarm In 6
4
Earth Ground
5
Alarm In 7
5
Analog Alarm 1
6
Alarm Ground
6
Analog Alarm 2
7
Ground
Содержание VG4-A-9543