20
en | Installing the Pipe Mount
AutoDome Pipe Mount
F.01U.251.410 | 1.0 | 2011.08
Installation Guide
Bosch Security Systems, Inc.
The following table lists the Power Supply Box connectors:
Table 2.1
Power Box Connections
Fuse Specifications
Volts
XF101 Mains
XF102 Camera
XF103 Heater
24 V
T 5.0 A
T 2.0 A
T 3.15 A
115 V
T 1.6 A
T 2.0 A
T 3.15 A
230 V
T 0.8A
T 2.0 A
T 3.15 A
No.
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Ground
Grounding Screw
P101 115/230 VAC or
24 VAC Power In
Line
NC
Neutral
P105
1
Control to Dome
(Fiber Optic
Model)
C-
(Biphase)
C+
(Biphase
)
Earth
Ground
RXD (+)
(RS-232/485)
TXD (-)
(RS-232/485)
Signal
Ground
P106
1
Control In/Out
(Optional)
C-
(Biphase)
C+
(Biphase
)
Earth
Ground
RXD (+)
(RS-232/485)
TXD (-)
(RS-232/485)
Signal
Ground
P107 24 VAC Power to
Dome Plug
Dome
24 VAC
Dome
24 VAC
Earth
Ground
Heater
(24 VAC)
Heater
(24 VAC)
1. Applicable to VG5 600 and 100 Series AutoDomes only.