58300000111195_ARA_en_f.doc – 02.06.09
Seite 34 von 102
4.7.3
Cam on the gear unit
The position of the brewing unit is detected with two microswitches S1
and S2. These two switches are able to define three positions.
When the appliance is switched on, the switch status of the
microswitches is checked and transmitted to the control module. The
brewing unit is moved to the basic position (= initialising).
Home position
Brewing position
Drainage position
S1 ON
S2 OFF
The brewing unit
is in the grinding
position and can
be filled.
Switch
S1
is
activated by
switch cam
(A)
.
Switch
S2
remains open.
S1 OFF
S2 ON
The transmission
turns clockwise
until switch
S2
is
closed by switch
cam
(A)
and
switch
S1
is open.
The brewing unit
is in the brew
position. The
transmission
motor stops.
Water can be
supplied and
coffee can be
brewed.
S1 ON
S2 ON
Once the brewing
process is complete,
the system is
drained.
For this, the motor
turns the cam disc
back by about 8°, so
that the drainage
valve is opened
again and the
remaining water can
run into the drip tray.
Switches
S1
and
S2
are closed.