58300000111195_ARA_en_f.doc – 02.06.09
Seite 59 von 102
5.7.23 Error
5
Upper symbol is lit,
lower row flashes:
Appliance is heating up.
Error 5
Heater or thermal fuse defective
(interrupted).
flashes
If this defect occurs while the
appliance is operating in a warm
state, the message “Unit is heating”
is displayed. The message is indi-
cated as long as the appliance
remains switched on.
When the appliance has been
switched off and after the cooling
phase, the message is indicated as
in the cold state.
5.7.24 Error
8
Upper symbol is lit,
lower row flashes:
Brewing unit cannot move
properly.
Error 8
Initialisation of the brewing unit
has failed.
flashes
The brewing unit cannot be moved into the
upper end position.
This may be due to several causes, e.g.:
►
Incorrect operation – the brewing
unit was filled with too much
pregorund coffee or with whole
coffee beans via the ground coffee
slot.
►
Incorrect operation – cleaning tablet
was inserted too early and blocked
the brewing unit.
►
Wrong coffee settings – too much,
too finely ground coffee.
►
Wrong grinding unit setting – grin-
ding too coarse, amount too large.
If the message does not go out when the appliance is switched off
and on again, disconnect the appliance from the mains and clean
the upper filter of the brewing unit.
If required, re-adjust the grinding unit setting.