58300000111195_ARA_en_f.doc – 02.06.09
Seite 71 von 102
6.5.2.3
Fin on the control lever of the brewing unit
It is possible that a cleaning tablet which is dropped in too early may
stick in the area of the control lever for the brewing unit. This results in
a blockage of the brewing unit and in the
Error 8
message. In the
worst case this may also cause the lever to jump out.
Therefore a fin
(A)
is also attached the control lever.
The control lever is a component of the brewing unit and is not
available separately. All current replacement brewing units feature this
new lever.
6.5.2.4 “Cleaning
process”
sticker
Information sticker to avoid damage caused by adding the cleaning
tablet at the wrong time is stuck to the inside of the right appliance
flap.
The information stickers are available as a spare part for service.