8.
Trouble Shooting
Error code Error code definition
Error code type
A0
Water temperature sensors defective
If a short or open circuit is detected on both water NTC
sensors the appliance will Lock.
Error is resolved when the sensor open or short circuit is
repaired.
Self-resolving
A1/E4
Box temperature protection
If temperature inside the appliance box is over 70ºC,
appliance
must start reducing its maximum power 5% every 30s
until box temperature drops below 70ºC. During this time
the ECU must show a warning. If at any time the box
temperature
goes over 80ºC or power is reduced more than
20%, appliance locks. Function is only active 30s after
opening the water.
Power reduction is reset when water is closed. Error is
resolved by manual reset.
Warning/ Lock out
A4
Air temperature sensor opened circuit
If a short or open circuit is detected on the air temperature
NTC, the appliance shuts down and goes to lockout.
Error is resolved by manual reset.
Lock out
A7
Outlet water temperature sensor defective
If a short or open circuit is detected on the outlet water NTC
sensor, a warning is shown.
Error is resolved when the sensor open or short circuit is
repaired.
Self-resolving
C7
Signal from fan not received
When no feedback signal is received from the fan, the unit
goes to lock.
Error is resolved by manual reset.
Lock out
CA
Water flow signal over specified maximum value
If the Control unit reads a water flow over the maximum
specified for the flow sensor (25l/min), appliance will lock.
Error is resolved when water flow is below 22 l/min again.
Self-resolving
CF
Exhaust blockage
If a pressure above normal operating conditions is detected
on the exhaust by fan speed and/or consumption, the
appliance is locked.
Error is resolved by manual reset.
Lock out
E1
Over-temperature detected
If the control unit detects an outlet water temperature over
85ºC, the appliance must shutdown and restart after the
outlet temperature goes below the setpoint value.
Self-resolving
E2
Inlet water temperature sensor defective
Self-resolving