Power bar indicator:
Indication of the current
operation power
Indicative Value (in %)
Note: each segment of the bar
represents 10% of power from 0
to maximum power in kW
Flame indication:
Indication of flame in the
burner
Symbol displayed when
ionization is detected - flame
presence
Warning symbol:
Error / warning symbol is turned
ON every time there is an error or
a warning
Connectivity
Connectivity symbol is ON when
a mobile device is connected to
the water heater wifi module
Tap symbol:
Indication of not enough power
to reach set point.
Note: In case symbol is displayed,
decrease (-) or increase (+) flow
accordingly
Excessive water flow symbol is ON
when the setpoint ±3ºC cannot be
reached at maximum
power because there is too much
water going through the water
heater, or at minimum power
because there is not enough water
going through the water heater
Solar application:
Indication that the automatic
solar function is activated,
meaning that the appliance is
receiving pre-heated inlet
water, with no need for burner
to start
The symbol is displayed and
burner is shutdown when T in
is under following conditions:
T
in
≥ T
set
– 1K
The symbol is deactivated and
burner restarted when:
T
out
< 60ºC
Fan operation:
Indication that the fan is in
operation
Fan rotation detection symbol is
ON when rotation of the fan
speed is detected
Table 7 – Display Symbols