Pict.24 – Inlet flow restrictor with filter
4.8
Water temperature sensors
The outlet and inlet water temperature is measured by a 8.5 kΩ NTC (outlet) and 50 kΩ
NTC (inlet). Both NTC measures temperature and are connected to different cable colors
and connectors in the control unit.
Pict.25 – Cold / Hot Temperature sensor
4.9
Box Temperature sensor
The Box air temperature is measured by a 10 kΩ NTC (See table with characteristic
values) and is assembled inside the room sealed box, in order to monitor the temperature
inside of the cabinet.
Pict.26 – Box air temperature sensor