5.3
Controls
5.3.1 Fascia panel mounted controls
Controls are easily removed from fascia panels by bending
console tabs.
Tools needed: T-20 Torx & flat blade screwdrivers
.
1. Remove fascia panel by removing T-20 Torx inner door
screws.
2. Disconnect wire harnesses from module after noting
connector locations.
3. Pry out metal console tabs holding module to console.
4. Carefully pry back plastic tabs, then slide module from
console.
5.3.2 Base mounted controls
Base mounted controls are located on the base between
circulation pumps and heaters, not behind fascia panels. So:
Dishwashers must be pulled out to change controls.
Dishwashers must be pulled out to measure voltages &
resistances.
5.3.2.1
To access base-mounted controls
Tools needed: T-20 Torx screwdriver & pliers
.
3.
Remove outer door
– see section 5.2.1.1
4.
Remove toe kick
– see section 5.2.1.2.
5.
Remove right/left side panels
– see section 5.2.1.3.
6.
Raise right side of tank
– see section 5.2.1.4.
5.3.2.2
To remove base-mounted controls
Locate control, open control cover and disconnect wire
harnesses from module after noting connector locations.
Push latch on back of control toward rear of dishwasher,
then slide control from base.
702_58300000148618_ara_en_a
Page 31 of 42
m
CAUTION
– 75% of all controls returned
for analysis check out OK. Most control
issues are due to loose connections.