198
en | System menus and dialogs
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
Transponder restriction
This option selects a transponder for the following restrictions:
No Restriction:
This selection is typically left at this setting at all
times. The output is not restricted by an individual transponder.
Only From Transponder Selected:
The selected events are only
output if they were reported from the transponder selected in
the transponder above.
All from Transponder Selected
:
All events are reported from
the transponder selected above. The selected events are
reported from all other transponders in the system.
Alarms
Outputs the information about an alarm including location, but
not the transponder and receiver levels. This is the data typically
sent to a printer.
Points, reporting alarm
Outputs the transponder and receiver levels for an alarm.
Typically, this is the data too detailed to send to a printer and is
used for diagnostics, not normal system operation.
Tests, single line
Outputs the simple information about a test. Typically, this is the
data normally sent to a printer.
Tests including point Info
Outputs the transponder and receiver levels for a test. This is the
data usually too detailed to send to a printer and is used for
diagnostics, not normal system operation. If this option is
selected,
Test, single line
above, would not be selected for the
same output device.
Transmitter low battery
Outputs low battery reports received from transmitters.
Operator activity log
Outputs all other operator activity (audit trail) not covered by
specific event selections.
Preferences changes
Outputs all changes made to system preference selections.
Database backup and
restore
Records all database backup and restore activity.
Operator database changes
Records all changes to the operator database.
Subscriber database
changes
Records all changes to the subscriber database.
Transponder data changes
Records all changes to the transponder database.
Spare 2
This is a future option that has no function at this time (leave
unchecked).
Report database changes
Records all changes to the
Alarm Report Database
.
Communications failure
Records all communication failures and restorations.
Transponder communication
Records all communications to transponders. This selection is
only used for engineering diagnostics. Leaving this item selected
generates a significant amount of history and fills up the hard
disk drive quickly. Leave this item unchecked.
Supervision monitor
Reports changes in the supervision status for all transmitters
that are being supervised.