Security Escort
System menus and dialogs | en
225
Robert Bosch (SEA) Pte Ltd
Training Manual
2017.08 | V2.18.1.0 | DOC
[Learn address]
Clicking this button on the master computer automatically
populates the master’s IP address in the
Master
’
s Network
Address
textbox, and the master’s network port in the
Master
’
s
Network Listen Port
textbox. Clicking this button on the slave
computer automatically populates the master’s IP address in the
Slave’s Network Address
textbox, and the master’s network
port in the
Slave
’
s Network Listen Port
textbox. If the computer
has more than one network interface card (NIC), you must verify
that the correct IP address was selected by comparing this
address to the IP address that was programmed in the Control
Panel TCP/IP protocol. If the address is not correct, manually
enter the correct IP address.
Remote Control Listening
Port
The Security Escort will be listening on this port to communicate
with the OPC server. A separate OPC server is created to
communicate between the OPC client and the Security Escort
system. The OPC server holds the alarm and trouble messages,
and sends the same to the available client once it is connected.
The OPC server will send the status of the Security Escort to the
OPC client. The OPC sever also acknowledges and deletes alarm
and trouble messages from OPC client. If the connection
between OPC server and Security Escort goes down, the OPC
server will try to reconnect with Security Escort. Once the
connection to the Security Escort becomes active, the Security
Escort will send all the available alarms to the OPC server. The
OPC server in turn sends the alarm back to OPC client; hence
the OPC client may display some duplicate alarms.
Master Database path
The path that this slave or workstation computer uses to access
the shared database files on the master computer. This path may
have a different drive letter on the different slave and
workstation computers. They are typically on the master
computer, but they may be on a file server or any other network
accessible drive.
Note: With version 2.04 and above of the
software, it is possible to use UNC path names instead of
mapping drive letters. Therefore, the path to the master
computer
’
s database would be “\\MASTER\ESCORT”.
Autobackup to the slave
database
If this option is checked, the slave computer will back up all
databases in the
Master Database path
to the
Slave Database
path
each night at 3:00 am.