Commissioning
Commissioning
8
DANGER
Risk of breaking hose lines due to overload or aging!
Danger to life, risk of injury!
Replace the hose lines after 6 years at the latest or if damage is visible.
f
According to EC Machinery Directive 2006/42/EC, commissioning must not be
undertaken until it has been determined that the machinery into which the drive
module is to be installed complies with the provisions of all relevant
guidelines/directives.
The combination of components may give rise to other types of hazard. It is there-
fore essential that the information in the operating instructions for the complete
machine be observed.
This applies in particular to "Mechanical hazards" that may result from mechanical
movements of the machine initiated by the drive modules and drives
(cylinders, motors).
First commissioning
8.1
Before commissioning
8.1.1
Ensure that the line system is in good, work-safe condition.
f
Open the taps in the cooling water line (if present).
f
Get the data sheets of the components to be assembled according to the
f
parts list ready.
Keep the suitable tool ready.
f
Compare the pressure adjustment of the type tested pressure relief valve with
f
the maximum admissible operating pressure of the accumulator (if available).
The pressure adjustment of the type tested pressure relief valve must not be
higher than the admissible operating pressure of the accumulator.
Adjust the electrical level monitoring and/or temperature measuring device
f
(if present) as required for operation of the machine.
Valve settings
8.1.2
Set pressure valves and flow control valves to the lowest settings possible.
f
Bring directional valves into the basic position.
f
Do not energize proportional valves to the command value.
f
Do not make any changes on sealed valves.
Do not change the factory settings. Do not set or adjust valves that, according
to the technical specifications (circuit diagram or parts list), have been