3.6 Engine start interlock
supply
-
battery
+
-
starter-
battery
+
-
engine
single engine
1
2
twin engine
1
2
3
4
2
configuration
start interlock
port
connection to
I/O-extension board 1
starboard
connection to
I/O-extension board 2
+
-
+
-
engine
+
-
+
-
engine
shielded cable
type LIYCY
2 x 0,75 mm
2
shielded cable
type LIYCY
2 x 0,75 mm
2
The relay "start interlock" is closed whenever the active control head is in neutral or warming up (see
5.4 "warming up") is active.
Wiring control unit
1
2
max. 30 V DC
max. 0,5
A
shielded cable
type
LIYCY
earthed at both ends
LED start interlock
1
2
potential-free
relay contact
closed
,
when
lever in neutral or
warming up active
engine start interlock via control unit
!
If inductive loads shall be switched, these must be provided with a free-wheeling diode.
If not, the digital output may be destroyed.
Wiring I/O-extension board
1
2
3
4
2
configuration
start interlock
potential-free
relay contact
max. 30V DC
max. 2 A
shielded cable
type LIYCY
2 x 0,75 mm
2
earthed at both ends
71
72
73
74
75
76
77
78
79
80
81
82
LED start-
interlock
1
2
3
4
closed when,
lever in neutral or
Warming Up active
!
If inductive loads shall be switched, these must be provided with a free-wheeling diode.
If not, the digital output may be destroyed.