11-6
Power connection
ECODRIVE DKC02.1 Drive Controller
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
11.4 Reaction of the drive to malfunctions
Power failure
If during a power failure the 24V control voltage for the drive controller is
buffered, the motor can be brought to a standstill by braking.
If during a power failure there is no 24 V control voltage, the motor be-
comes torque-free and coasts to a standstill.
DANGER
Dangerous movements!
Danger may result in equipment damage, personal injury
or death!
⇒
Stay away from the machine’s movement area. Pos-
sible measures to be taken to prevent access by un-
authorized persons:
- protective fence
- protective railing
- protective covering
- light barrier
⇒
Fences and coverings should be strong enough to
withstand the maximum possible momentum.
24 V control voltage failure for the DKC
If the 24 V control voltage for the DKC fails, the motor can no longer be
brought to a standstill by braking. The motor becomes torque-free and
coasts to a standstill.
DANGER
Dangerous movements!
Danger may result in equipment damage, personal injury
or death!
⇒
Stay away from the machine’s movement area. Pos-
sible measures to be taken to prevent access by un-
authorized persons:
- protective fence
- protective railing
- protective covering
- light barrier
⇒
Fences and coverings should be strong enough to
withstand the maximum possible momentum.