4-10
ECODRIVE DKC drive controllers
ECODRIVE DKC02.1 Drive Controller
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
X3 zero switch, sensor, travel limit switch, diagnostic outputs
Maximum wire cross section which can be connected: 2.5 mm
2
X3
1
2
3
4
5
6
Zero switch
Measure button 1
Measure button 2
Travel limit positve
Travel limit negative
NS
MT1
MT2
LIMIT +
LIMIT -
+24V
free
E-STOP
0VM
X4
1
2
3
4
5
6
DC +24 V ±20% Control voltage connection
Ready to
operate
Bb1
Bb1
0V Zero reference to control voltage
FP5103F5.fh5
Input voltage
HIGH
LOW
Input resistance
min. max.
16 V 30 V
-0,5 V 8 V
ca. 8 kOhm
10k
10n
2k
6k3
Fig. 4-15: Inputs for zero switch, sensor, and travel limit switch
AP0246D4.fh5
z. B. oscilloscope
CH1
CH2
min.
AK1-0V; AK2-0V
Outputs:
max.
Output voltage
- 10 V
+ 10 V
DA-transformer
8 Bit
Resolution per bit
78 mV
7
8
9
10
AK1
0V
AK2
X3
Fig. 4-16: Connection assignments of the diagnostic outputs
Zero switch, sensor, travel limit
switch
Diagnostic outputs