4-2
ECODRIVE DKC drive controllers
ECODRIVE DKC02.1 Drive Controller
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
Technical data
Power connection / Power section
Symbol
U
N
S
MAX
I
EIN
f
S
I
TYP
I
PEAK
P
V
P
BM,DKC
P
BD,DKC
W
MAX,DKC
W
ZW,DKC
C
DKC
U
ZW
f
S
= 4 kHz
V
kVA
A
kHz
A
A
W
kW
kW
kWs
Ws
mF
V
40
40
180
10
0,15
5,0
15
0,15
DC 500...800
DKC02.1-040-7-FW
3 x AC (380 ... 480)
4,8 ... 9
9 ... 12
± 10%
f
N
Hz
50...60
4 or 8
I
CONT
A
16
f
S
= 8 kHz
I
CONT
A
12,5
TB5101D4.fh5
1)
1)
2)
2) Value dependent on power input voltage
Designation
Operating mode at the mains
Mains input voltage
Maximum conn. voltage
Making current
Switching frequency (selectable)
Continous current at
Rated current
Peak current
Power disspation, without
bleeder dissipation
Peak bleeder output DKC
Continous bleeder output DKC
Maximum feedback energy DKC
Storage energy DKC
DC bus capacitance
DC bus voltage
Unit
(Permissble load cycle equals 0.5 sec. on, 33 sec. off.)
three-phase
Mains frequency
Continous current at
1) The drive data for 4 and 8 kHz switching. frequencies are listed in the document "ECODRIVE DKC servo drive" - Selection Data.
Fig. 4-2: Technical data for the power connection and power section
DC 24V voltage supply
Symbol
U
N,DC
w
Designation
Control voltage connection
for DKC
Input voltage
Maximum ripple content
Current consumption
Voltage connection for
holding brake
Unit
V
%
0,7
DC (19,2 ... 28,8) V
DKC02.1-040-7-FW
must not exceed the input voltage range
I
N,DC
A
U
N,HB
w
Input voltage
Current consumption
V
%
please see MKD dokumentation
DC (21,6 ... 26,4) V
I
N,HB
A
TB5102D4.fh5
must not exceed the input voltage range
Maximum ripple content
Fig. 4-3: Technical data DC +24V voltage supply
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01