6.2.12 Fan unit
To connect the fan unit, use a connection cable 3 x 0.75 mm
2
.
MS2Nxx-xxxxA (U
N
230 V )
MS2Nxx-xxxxB (U
N
115 V)
Assignment
Connection
1
L1 230 V
Screw connection 0.5 ... 1.5 mm
2
2
N
3
L1 115 V
PE
Tab. 6-23: Assignment of connector fan unit MS2N
The plug insert can be mounted in any position into the connector
housing. Therewith, the cable output direction can be done in steps
of 90 degrees.
Mounting instruction fan connector
1. Dismantle the fan connector
- Removing the housing screw (4)
- Dismount plug insert
- Loosen the cable gland and remove single parts, screwed connection (1),
washer (2) and sealing (3)