![Bosch Rexroth Hagglunds CA 10 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-ca-10/rexroth-hagglunds-ca-10_installation-and-maintenance-manual_43004034.webp)
Commissioning 33/52
Bosch Rexroth Mellansel AB
, Installation and maintenance manual, Hägglunds CA 10 - CA 40, RE 15354-WA/04.2015
8 Commissioning
NOTice
Dirt particles!
A not run-in motor in combination with dirt particles in the oil can badly affect the
sliding surfaces in the motor. This is valid during the first 100 hours.
▶
The Hägglunds radial piston hydraulic motor must be installed and commisioned
in a clean condition.
8.1 Commissioning
Check the following points before commissioning the motor, i.e. before starting the
first time:
•
Make sure that all fluids has been removed from the motor to prevent accidental
mixing with the hydraulic fluid used in the system.
•
Check that the motor is connected to give the correct direction of rotation, see
7.3.6: Direction of rotation of motor shaft.
•
Select the hydraulic fluid in accordance with the recommendations,
and
data sheet RE 15414, Hydraulic fluid quick reference.
8.1.1
Oil filling
1.
Fill the motor housing with hydraulic fluid via a filter into the drain outlets D1,
D2 or the vent hole (depending on how the motor is mounted), see
2. Check the drain line to ensure that excessive pressure does not build up in the
motor case; see chapter
and
3. Check that the motor is protected from overloads, see chapter
.
4. Check that the charge pressure conforms to the charge pressure curve, see
chapter
15.1.2: Recommended charge pressure
.
5. Check that all hydraulic couplings and plugs are properly tightened to prevent
leakage.