Transport and storage
19/52
Bosch Rexroth Mellansel AB
, Installation and maintenance manual, Hägglunds CA 10 - CA 40, RE 15354-WA/04.2015
Table 5: Oil volume
Motor
Oil volume approx.
litres
US gal.
CA 10
0.7
0.19
CA 20
1.0
0.26
CA 30
1.1
0.29
CA 40
1.2
0.32
Fig. 8: Filling the motor with oil
6.2.2 Storing for extended periods or in uncontrolled environment
NOTice
Insufficient cleanliness!
Risk of damage to equipment.
▶
Take extreme care to ensure that no contamination enters the motor.
If the motor is stored for more than 3 months in an uncontrolled environment or
more than 12 months in a controlled environment, it must be filled with oil.
1
Place the motor as shown in
Fig. 7: Hägglunds CA 10 - CA 40 standing on a flat
, alt.A) Standing with shaft horizontal.
2
Fill the motor with filtered oil in the following order: D1, A1, C1.
NOTE!
.
3
Seal connections A1 and C1 with the plugs fitted to the connection surface at
delivery. Check that the O-rings or rubber seals are in position on the plugs.
4
Fit the plug to D1.
5
Position the motor as shown in
Fig. 7: Hägglunds CA 10 - CA 40 standing on a flat
, alt. A) Standing with shaft horizontal. or B) Standing with shaft vertical.
DD00070796