![Bosch Rexroth Hagglunds CA 10 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-ca-10/rexroth-hagglunds-ca-10_installation-and-maintenance-manual_43004026.webp)
Installation 25/52
Bosch Rexroth Mellansel AB
, Installation and maintenance manual, Hägglunds CA 10 - CA 40, RE 15354-WA/04.2015
7.3.3 Draining and venting the motor
Horizontal mounting
When the motor is installed with the shaft in the horizontal plane, the highest of the
two drain outlets D1 or
D2 must always be used (see
Fig. 12: Draining and venting,
horizontal mounting and Fig. 13: Positioning of drain connection / Maximum angle of
shaft page 26)
Drain line must be connected to the tank with a minimum of restrictions, to ensure
that the maximum case pressure is not exceeded.
For manintenance, see chapter
Fig. 12: Draining and venting, horizontal mounting
The case drain fluid must
be directed to reservoir via
the highest located drain
connection, D1 or D2
Drain connection
D1
Drain connection
D2
DD00069615