![Bosch Rexroth Hagglunds CA 10 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-ca-10/rexroth-hagglunds-ca-10_installation-and-maintenance-manual_43004042.webp)
Technical data 41/52
Bosch Rexroth Mellansel AB
, Installation and maintenance manual, Hägglunds CA 10 - CA 40, RE 15354-WA/04.2015
15 Technical data
15.1 Technical data, Hägglunds CA 10 - CA 40
15.1.1 Motor data
Table 18: General data (metric)
Frame size
CAB 10
CAB 20
CAB 30
CAB 40
Type of mounting
Pipe connections
Shaft loading
See
RE 15354 Data sheet 4.8 Permitted external loads
Hydraulic fluids
Pressure
Maximum operating pressure
bar
250
250
250
250
Maximum peak pressure
bar
320
320
320
320
Charge pressure
bar
15.1.2: Recommended charge pressure
Maximum case pressure
bar
3
3
3
3
Maximum case peak pressure
1)
bar
8
8
8
8
Temperature limits of case drain oil
Seal type: NBR
Minimum
°C
-30
-30
-30
-30
Maximum
°C
+70
+70
+70
+70
Oil volume in motor case
l
0.7
1.0
1.1
1.2
Moment of inertia for rotary group
kg·m
2
0.076
0.146
0.210
0.275
Weight
kg
46
63
80
95
1)
Momentary pressure spikes t< 0.1 s of up to 8 bar are permitted
Table 19:
Specific data (metric)
Frame size Nominal size
Specific torque
Displacement
Maximum torque
Maximum speed
Maximum
operating power
2)
Nm/bar
cm
3
/rev
Nm
rpm
kw
CAB 10
0008
8
503
1 945
350
70
0010
10
628
2 430
350
86
0012
12.5
785
3 040
350
105
CAB 20
0016
16
1 005
3 890
350
139
0018
18
1131
4 375
350
155
0020
20
1257
4 860
350
171
0022
22.5
1414
5 470
350
190
0025
25
1571
6 075
350
209
CAB 30
0028
28
1 759
6 805
350
226
0030
30
1 885
7 290
330
226
0032
32.5
2 042
7 900
290
216
0035
35
2 199
8 505
290
233
0037
37.5
2 356
9 115
260
224
CAB 40
0040
40
2513
9 720
280
257
2)
Flushing of motor case is required. See