4/27
Bosch Rexroth Canada I March 2021 ı Revision 3.0
2 Set up for Basic Operation
To enter Programming mode from the operator screen, press the program mode icon with the
USB Program key inserted.
2.1 System Configuration
1.
Set the units to imperial (LBS/Mile) or metric (Kg/Km).
2.
Set the TRUCK ID.
3.
Set the REGION NAME.
4.
Set the DRIVER ID (optional), 4 driver IDs allowed.
Note: Configuring driver ID to ‘USER” enables operators to enter user defined driver ID on operator screen.
5.
Set the type of Temperature Sensor (optional).
6.
Set the Options – see Option Checkboxes in this manual
7.
Set the items that the user has access to (optional).
8.
Set Blast Timer, 0-timer disabled (optional). This should be set less than Err01 delay.
9.
Set Percentage of Temp. compensation when there is a 3 degree change (optional).
10.
Set the vehicle speed alarm (optional).
11.
Select auxiliary options (check marks)
Press here to enter program
mode. If Icon is not colored,
the PGM key is not inserted
or it is the wrong key
.
Main Page
Secondary Page
Joystick Page
Speed Calibration
Conveyor Valve
Spinner Valve
Gate Valve
Prewet Valve
Anti-Ice Valve
Solid Material Calibration
Prewet Material Calibration
Anti-Ice Material Calibration
Swipe up/dn to see more
checkboxes
Swipe up/dn to see
more checkboxes
Содержание Rexroth CS660