F037 300 069 (2015.09.02)
9
- The connection has been established properly.
- The cables have been laid correctly.
- All screws have been tightened securely with the specified torque.
- The device functions perfectly.
2.3.6.
I
NSPECTION AND MAINTENANCE
It is recommended to perform inspection and maintenance in accordance with DIN EN 60079-
17:2008-05 / DIN EN 60079-1:2008-04 standards.
Ensure that the CIMS housing is not damaged. Especially if the flame paths show evidence of
wear, distortion, corrosion or other damage, the diametric clearance must be checked. Contact
Bosch Rexroth for the valid dimensions and clearances.
The bolts which fix the cover and housing base onto the intermediate piece (see Figure 4) are
made out of stainless steel, quality A4-70, which needs to be maintained and are only to be
replaced by bolts delivered by Bosch Rexroth, see Section 7.1.
Repairing the sensor is not permitted. A defect CIMSmart has to be replaced by trained personnel.
The operator of the control, regulating and display device must keep it in good condition, operate it
correctly, monitor it and clean it regularly
- Visually inspect the threaded gap.
- Visually inspect the flameproof encapsulation for damage.
- Check sealings for effectiveness.
- Replace old or damaged sealings with new original seals.
- Check that the connecting terminals, cable & conductor entries are secure.
In the course of maintenance particular attention must be paid to checking that the parts essential
for the type of protection and proper functioning are in good condition.
The threaded gaps must be protected.
They must not be machined or varnished at any time later.
Do not use the CIMSmart with defective parts in the flameproof encapsulation, please contact
supplier, these parts have to be replaced with original parts immediately.
Only authorized qualified personnel may do any of the work relating to maintenance and fault
clearance.
Never open or remove housing cover and/or the Ex cable gland in an explosive atmosphere.
Only perform tasks if the possibility of an explosive atmosphere has been excluded.
Consider all following special conditions for safe use.
DIN EN 60079-17:2008-05 must be observed.
Safety instructions for maintenance
Warning: Explosion hazards when performing maintenance!
The presence of ignition sources such as sparks, open flames and hot surfaces can cause
explosions in the hazardous area.
-
Obtain a written work release prior to starting the maintenance tasks.
-
Only perform maintenance tasks if the possibility of an explosive atmosphere has been
excluded.
-
Only use tools authorized for use in the ex-zone.
-
Do not weld on the sensor.
-
Do not use the sensor as an earth point when welding.
Non-observance of these instructions results in the loss of explosion protection.
Содержание Rexroth CIMSmart
Страница 2: ...F037 300 069 2015 09 02 2 ...
Страница 29: ...F037 300 069 2015 09 02 29 ...
Страница 32: ...F037 300 069 2015 09 02 32 CIMSMART DRAWINGS A 1 F 037 A00 002 CIMS MK IV CIMSMART STANDARD VERSION NON ATEX ...
Страница 33: ...F037 300 069 2015 09 02 33 ...
Страница 34: ...F037 300 069 2015 09 02 34 ...
Страница 35: ...F037 300 069 2015 09 02 35 ...
Страница 36: ...F037 300 069 2015 09 02 36 A 2 F 037 A00 004 CIMS MK IV CIMSMART ATEX VERSION ...
Страница 37: ...F037 300 069 2015 09 02 37 ...
Страница 38: ...F037 300 069 2015 09 02 38 ...
Страница 39: ...F037 300 069 2015 09 02 39 ...
Страница 40: ...F037 300 069 2015 09 02 40 Appendix B DRAWING 3 033701 MOUNTING BORE PATTERN ON CYLINDER ...
Страница 79: ...F037 300 069 2015 09 02 79 Appendix E DECLARATION OF CONFORMITY EMC DIRECTIVE 2004 108 EC ...
Страница 80: ...F037 300 069 2015 09 02 80 Appendix F DECLARATION OF CONFORMITY ATEX DIRECTIVE 94 9 EG ...
Страница 81: ...F037 300 069 2015 09 02 81 ...
Страница 82: ...F037 300 069 2015 09 02 82 ...
Страница 83: ...F037 300 069 2015 09 02 83 ...
Страница 84: ......