F037 300 069 (2015.09.02)
58
Diagnostic Trouble Codes
Event
Id
Event
Event Type
01h
Supply voltage of CIMS out of spec (too high)
Error
02h
Temperature of CIMS out of spec (too high, too low)
Warning
03h
Piston rod speed out of spec (too high)
Warning
04h
Piston rod acceleration out of spec (too high)
Warning
05h
Analogue voltage of Hall signal out of range
Error
06h
Signal amplitude too low (air gap of CIMS out of spec, too high)
Error
07h
Signal amplitude estimation invalid (signal processing)
Warning
08h
Calculated center point invalid (signal processing)
Warning
09h
Application not valid
Error
0Ah
Read of "OperationData" file during system startup has failed.
Error
0Bh
Read of "DeviceInfo" file during system startup has failed.
Error
0Ch
Read of "ProductionDataErr" file during system startup has failed.
Error
0Dh
Read of "OccasionalWrittenDataErr" file during system startup has failed.
Error
0Eh
Read of "CyclicWrittenDataErr" file during system startup has failed.
Error
0Fh
Writing of "OccasionalWrittenData" file has failed.
Error
10h
Writing of "CyclicWrittenData" file has failed.
Error
11h
The statistics counter "NrOfPistRodStandstills" has reached the maximum. Information
12h
The statistics counter "TotalTravelledDistanceAtHighSpeed" has reached
the maximum.
Information
13h
The statistics counter "TotalTravelledDistanceAtLowSpeed" has reached
the maximum.
Information
14h
The statistics counter "StrokeLengthDistribution1" has reached the
maximum.
Information
15h
The statistics counter "StrokeLengthDistribution2" has reached the
maximum.
Information
16h
The statistics counter "StrokeLengthDistribution3" has reached the
maximum.
Information
17h
The statistics counter "StrokeLengthDistribution4" has reached the
maximum.
Information
18h
The statistics counter "StrokeLengthDistribution5" has reached the
maximum.
Information
19h
The statistics counter "StrokeLengthDistribution6" has reached the
maximum.
Information
1Ah
The statistics counter "TemperatureClassification1" has reached the
maximum.
Information
1Bh
The statistics counter "TemperatureClassification2" has reached the
maximum.
Information
1Ch
The statistics counter "TemperatureClassification3" has reached the
maximum.
Information
1Dh
The statistics counter "TemperatureClassification4" has reached the
maximum.
Information
1Eh
The statistics counter "TemperatureClassification5" has reached the
maximum.
Information
1Fh
The statistics counter "TemperatureClassification6" has reached the
maximum.
Information
Содержание Rexroth CIMSmart
Страница 2: ...F037 300 069 2015 09 02 2 ...
Страница 29: ...F037 300 069 2015 09 02 29 ...
Страница 32: ...F037 300 069 2015 09 02 32 CIMSMART DRAWINGS A 1 F 037 A00 002 CIMS MK IV CIMSMART STANDARD VERSION NON ATEX ...
Страница 33: ...F037 300 069 2015 09 02 33 ...
Страница 34: ...F037 300 069 2015 09 02 34 ...
Страница 35: ...F037 300 069 2015 09 02 35 ...
Страница 36: ...F037 300 069 2015 09 02 36 A 2 F 037 A00 004 CIMS MK IV CIMSMART ATEX VERSION ...
Страница 37: ...F037 300 069 2015 09 02 37 ...
Страница 38: ...F037 300 069 2015 09 02 38 ...
Страница 39: ...F037 300 069 2015 09 02 39 ...
Страница 40: ...F037 300 069 2015 09 02 40 Appendix B DRAWING 3 033701 MOUNTING BORE PATTERN ON CYLINDER ...
Страница 79: ...F037 300 069 2015 09 02 79 Appendix E DECLARATION OF CONFORMITY EMC DIRECTIVE 2004 108 EC ...
Страница 80: ...F037 300 069 2015 09 02 80 Appendix F DECLARATION OF CONFORMITY ATEX DIRECTIVE 94 9 EG ...
Страница 81: ...F037 300 069 2015 09 02 81 ...
Страница 82: ...F037 300 069 2015 09 02 82 ...
Страница 83: ...F037 300 069 2015 09 02 83 ...
Страница 84: ......