Installation 31/64
RE 92750-01-B/06.2018, A10VG, Series 10,
Bosch Rexroth AG
▶
Make sure the working environment at the installation site is completely free of
dust and foreign substances. The axial piston unit should be clean when installed.
Contamination of the hydraulic fluid can considerably affect the function and
service life of the axial piston unit.
▶
Use fiber-free cloths for cleaning.
▶
Use suitable, mild cleaning agents to remove lubricants and other heavy
contamination. Do not allow cleaning agents to enter into the hydraulic system.
7.3 Installation position
The axial piston unit can be installed in the following positions. The pipeline routing
shown illustrates the basic layout.
If filling the stroking chambers via X
1
and X
2
is not possible in the final installation
position, then fill before installation, e.g., in installation position 2.
In order to prevent unexpected actuation and damage, the stroking chambers
must be air bled.
If air bleeding of the stroking chamber through ports X
1
and X
2
is not possible on
account of the installation situation, the air can be pushed out of the stroking
chambers by slowly and repeatedly swiveling the axial piston unit out in both
directions. Make sure that the machine or the system is in a safe state during the
air bleed process.