17553v1.0
9
3.2.3 PC to Door Controller Configuration
After completing
Section 3.2.2,
the UDS needs to be configured to communicate with the PC.
Configuration
From the
basic parameters menu
(see previous section) select
1
and press
Enter
.
Baudrate (9600)
9600 <enter>
I/F Mode (4C) ?
4C <enter>
Flow (00) ?
00 <enter>
Port No (10001) ?
nnnnn <enter>
ConnectMode (C0) ?
Cn <enter>
Datagram Type (00) ?
01 <enter>
Remote IP Address : (000)
192.
(000)
168.
(000)
101.
(000)
3 <enter>
Remote Port (00000) ?
00000 <enter>
Pack Cntrl (00) ?
00 <enter>
SendChar 1 (00) ?
00 <enter>
SendChar 2 (00) ?
00 <enter>
Enter the following information:
Baudrate
Press
Enter
to accept the default value.
I/F Mode
Press
Enter
to accept the default value.
Flow
Press
Enter
to accept the default value.
Port No
Enter the
port number
and press
Enter
.
ConnectMode
Enter the
connect mode
for the administration software and press
Enter
.
Datagram Type
Enter the value
01
and press
Enter
.
Remote IP Address
Enter
IP address
of the PC and press
Enter
.
Remote Port
Press
Enter
to accept the default value.
Pack Cntrl
Press
Enter
to accept the default value.
SendChar 1
Press
Enter
to accept the default value.
SendChar 2
Press
Enter
to accept the default value. The menu will now be displayed again.
Change Setup : 0 Server configuration
1 Channel 1 configuration
7 Factory defaults
8 Exit without save
9 Save and exit Your choice ?
Select
9
(Save and Exit) and press
Enter
. Configuration of the UDS is now complete.