Bosch Security Systems | 2008-12
PRS-1AIP1 IP Audio Interface
| Installation and User Instructions | Introduction
en
| 7
6 Control Inputs 1..4
Default: open contacts (non isolated, 0 is connected to
ground)
•
1-2: CI1
•
3-4: CI2
•
5-6: CI3
•
7-8: CI4
7 Control Inputs 5..8 and Fault Relay out
Default: open contacts (non isolated, shared 0 is
connected to ground, internal pull-up current source)
•
1-2: CI5
•
3-2: CI6
•
4-5: CI7
•
6-5: CI8
Fault Relay out
Default (no fault): open contacts (voltage free relay
contact)
•
7-8: Fault contact
8 Audio Output 2
Balanced, line level with pilot tone generation
•
1: -
•
2: ground
•
3: +
9 Audio Output 1
Balanced, line level
•
1: -
•
2: ground
•
3: +
10 Audio Input 2
Balanced, line level with pilot tone detection
•
1: -
•
2: ground
•
3: +
11 Audio Input 1
Balanced, microphone/line level, microphone
supervision
•
1: -
•
2: ground
•
3: +
12 RS-232 serial port
D-Sub, 9-pole male
13 Ethernet 1
RJ45 for network connection 10/100 Mbps with status
indicators
•
Green ON: network connection established
•
Green OFF: no network connection
•
Yellow ON/flashing: data communication
•
Yellow OFF: no data communication
14 Ethernet 2 (back-up connection for redundancy)
RJ45 for network connection 10/100 Mbps with
indicators as for Ethernet 1
15 RS-485 bus
For future use; RS-485 interface is not supported
•
1: A (TxD-/RxD-)
•
2: C (reference). Connected via a 100 ohm resis-
tor to the ground, which is connected to the nega-
tive input terminal of the power supply.
•
3: B (TxD+/RxD+)
16 Back-up power supply input
with battery under-voltage detection
•
1: +
•
2, 3: ground
17 Mains power supply input
with mains power failure detection
•
Centre: +
•
Ring: ground
Caution
Do not connect a voltage or current source to
the Control Input contacts.