Bosch Security Systems | 2008-12
PRS-1AIP1 IP Audio Interface
| Installation and User Instructions | Configuration
en
| 17
3.2.10 Serial (RS-232)
This function is used for end-to-end serial data
tunnelling with relatively low speed. This function is
typically used for remote control, e.g. Pan/Tilt/Zoom
control of a camera.
Select the RS232 communication parameters as needed
by the application and the connected devices. The serial
parameters can be chosen independently at both ends of
the communication. When tunneling, only the data is
transmitted end to end, the RS232 control signals are
only of local significance.
The serial input is automatically detected and the device
supports both binary and formatted data streams.
All data received from the network in one IP packet will
be transmitted in one block without framing, formatting
or the addition of extra characters.
Submit / Cancel button
Submit saves the set values, restarts the device and
returns back to the last screen. Cancel restores the last
submitted values.
3.2.11 SNMP
The IP Audio Interface contains an SNMP agent that
can report the device status information to a managing
system using a Trap protocol operation.
Trap Target IP Address
Default: 0.0.0.0
Enter the IP address of the SNMP trap destination.
Submit / Cancel button
Submit saves the set values, restarts the device and
returns back to the last screen. Cancel restores the last
submitted values.
l
figure 3.11: Serial (RS-232) screen (default)