14
| English
1 609 929 X70 | (25.1.11)
Bosch Power Tools
Technical Data
Operation
Starting Operation
f
Observe correct mains voltage! The voltage
of the power source must agree with the
voltage specified on the nameplate of the
machine. Power tools marked with 230 V
can also be operated with 220 V.
Switching On
PHG 500-2:
Press the On/Off switch
4
to posi-
tion
I
or
II
.
PHG 600-3:
Press the On/Off switch
4
to posi-
tion
I
,
II
or
III
.
PHG 630 DCE:
Press the On/Off switch
5
to po-
sition
I
,
II
or
III
.
Thermal-protection shut-off:
In case of over-
heating (e.g. due to air build-up), the power tool
automatically shuts off the heating system, but
the blower will continue to run. When the power
tool has cooled down to the operating tempera-
ture, the heating system is automatically
switched on again.
Switching Off
PHG 500-2/PHG 600-3:
Press the On/Off switch
4
to position
0
.
PHG 630 DCE:
Press the On/Off switch
5
to
position
0
.
PHG 600-3/PHG 630 DCE:
After working for a
longer time with high temperature, allow the
power tool to cool down by running it in the cold
air setting
I
before switching off.
Hot Air Gun
PHG 500-2
PHG 600-3
PHG 630 DCE
Article number
0 603 29A 0..
0 603 29B 0..
0 603 29C 7..
Rated power input
W
1600
1800
2000
Air flow
l/min
240/450
250/350/500
150/300/500
Temperature at the nozzle outlet
(approx.)
°C
300/500
50/400/600
50–630
Temperature-measuring accuracy
– at the nozzle outlet
– on the display
±
10 %
–
±
10 %
–
±
10 %
±
5 %
Display operating temperature*
°C
–
–
0...+50
Weight according to EPTA-Procedure
01/2003
kg
0.75
0.8
0.9
Protection class
/
II
/
II
/
II
* The display can turn black when not within the operating temperature.
The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries,
these values can vary.
Please observe the article number on the type plate of your machine. The trade names of the individual machines
may vary.
OBJ_BUCH-1348-001.book Page 14 Tuesday, January 25, 2011 1:51 PM