English 5
Countertop Requirements
Mounting Requirements
Use the mounting brackets supplied. See “Attach Brackets to the Cooktop” on
page 6. and “Install the Cooktop” on page 6 for further details.
Ventilation Recommendations
We strongly recommend the installation of a ventilation hood above this appli-
ance. The hood must be installed according to instructions furnished with the
hood.
Figure 2: Cutout Dimensions
21” (533.4 mm) cooktop depth
4” (101.6 mm) Below Countertop
to Left Side Wall
7-3/8” (187.8 mm) Min.
2-1/4” (57.2 mm) Min. to
Counter Front
Clearance From
6” (152.4 mm)
Min. to Left
1-3/4” (44.5 mm) Min. to
Combustible Wall
to Right Side Wall
to Right Side
Wall
Side Wall
Cooktop to Start
of Radius
4-3/8” (111.6 mm) Min.
3” (76.2 mm) Min.
1/8” (3.5 mm) Min.
Table 2: Cutout Dimensions
# Cooktop
30” Models
36” Models
45” Models
A
Cutout
19-1/8” to 19-7/8”
(486.1 to 505.6 mm)
19-1/8 to 19-7/8”
(486.1 to 505.6 mm)
19-1/8 to 19-7/8”
(486.1 to 505.6 mm)
B
Cutout
28-5/8” to 29-3/8”
(727.2 to 746.6 mm)
34-5/8” to 35-3/8”
(879.6 to 899 mm)
43-15/16” to 44-1/2”
(1116.2 to 1130.6
mm)
C
Corner
30” (762 mm)
36” (914.4 mm)
45” (1143 mm)
D
Overall
31” (787.4 mm)
37” (939.8 mm)
46” (1168.4 mm)