English 4
•
Natural Gas
- 6 inches water column (14.9 Millibars) minimum.
•
Propane Gas
-11 inches water column (27.4 Millibars) minimum.
The propane gas tank must be equipped with its own high pressure regulator in
addition to the pressure regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP conversion kit – Model
NEZ10
56
, must be purchased separately. A qualified technician or installer must
do the conversion.
Note: NGP model cooktops cannot be converted for LP use.
Cabinet Requirements
Dimension requirements in Figs. 1 & 2 are for combustible surfaces. When the
surface is protected by a material listed by UL as a Floor Protector and Wall
Shield covered with not less than No. 28 MSG sheet metal 0.015 inch (0.38mm)
stainless steel, 0.024 inch (0.6mm) aluminum or copper, it is considered noncom-
bustible and some dimensions may be reduced. For a noncombustible surface
over the cooktop, the minimum clearance is 24" (61cm) rather than 30" (76cm) .
•
Instructions are based on standard American cabinets 36" high (91cm) x 24"
deep (61cm) with a 25" (63cm) countertop.
•
Provide approximately a 10 square inch opening (65cm
2
) in the toe kick area
or other cabinet area for adequate air inlet to the cabinet.
NOTE:
All measurements given have to be precisely followed. If nonstandard
cabinets are used, make sure they are installed with minimum dimensions shown
in fig. 1 and fig. 2.
Plan the installation of the unit so that the power cord, gas shut-off valve and gas
pressure regulator are accessible from the front of cabinet. If a drawer is installed
directly under the cooktop, its depth (front to back) should be no greater than 15"
(38cm).
Figure 1:
Installed Dimensions (from cooktop edges
)
Depth from Back Wall
Cabinet 13" (33cm) max.
Hood Depth - 24" (61cm) max.
Centered Over Cooktop
Rear Wall - 1-3/4"(4cm)
Right Side
3" (8cm) min.
Left Side
6" (15cm) min.
18" (46cm) min.
Above Counter - 30" (76 cm) min. to
Combustible Surface
NGT(P)7x - 30" (76cm) min.
NGT(P)9x - 36" (91cm) min.
Содержание NGP Series