MON152CL |
Instruction Manual
|
Installation
Bosch Security Systems | 22 September 2003
EN
| 12
3
OPERATION
3.1
Front Panel Controls (Fig. 1)
Input (#1)
Selects CVB1, CVB2, Y/C and VGA.
Display of CVB1, CVB2, S-video and PC.
Menu (# 2)
Selects on-screen display (OSD), enters data,
saves settings
Multifunction Controls
(# 3) &
(#4)
First push selects
Brightness
or
Contrast
functions for adjustment.
(#5) &
(#6)
Within OSD Menu: Moves cursor to the left
or decreases adjustment levels; Moves cursor
to the right or increases adjustment levels.
(#7)
Power
On/off
control for LCD Flat Panel
Display
Amber LED: indicates power
on
to base,
power
off
to LCD Display
Green LED: indicates power
on
to base, power
on to LCD Display
Flashing Amber LED: indicates "Sleep mode" on
VGA input.
3.2
On-screen Display (OSD) Menu (Multilanguage)
Video mode
Press
Menu
(
Fig. 1 item 2
) for the following menu options:
3.2.1
FUNCTION
Control (#3)
Control (#4)
Brightness Select
Contrast Select
FUNCTION
Control (#5)
Control (#6)
• Brightness Level Decrease
• Brightness Level Increase
• Contrast Level Decrease
• Contrast Level Increase
• Adjustment Decrease
• Adjustment Increase
Within OSD Menu: Moves cursor upward;
Moves cursor downward.
Tint
Adjusts tint level; for best results, adjust until
skin color is natural.
NOTE: Applicable to NTSC only; not
available in PAL format.
Color
Adjusts the overall color intensity of the screen.
Default
Enables factory default settings for brightness,
contrast, tint, color, and volume.
Language
Selects the language for the OSD text,
available in English, French, German, Italian,
and Spanish, Dutch and Portuguese.
Channel Title
Allows selection and enabling of 16-character
title per input channel.
3D Comb Filter
Enable comb filter to attain the best video
performance.
NOTE:
If monitor is connected with a
line-lock camera directly, this function should
be in "manual mode" to attain the better
resolution.
AGC
Automatic gain control.
NOTE:
The factory default setting is "Auto".
Under Scan
Enable or Disable the Under Scan function.
PIP Menu
Selects picture-in-picture application.
Power on option
Selects the video input to be displayed upon
power-up after a power interruption. The
factory default setting is CVB1.
Volume
Adjusts the volume for the audio inputs.
Exit
Exit the OSD Menu and returns to standard
monitor display.
3.2.2 VGA mode
Auto set
Automatic adjusting of H position, V position,
phase and clock values.
Display setting
Adjusts the H position, V position, fine tune,
sharpness, and track.
NOTE:
Track means, section of filter for
best performance
Color temperature
Selects the color temperature of the LCD
monitor.
Language
Selects the language for the OSD text,
available in English, French, German, Italian,
and Spanish, Dutch and Portuguese.
Volume
Adjusts the volume for the audio inputs.
Default
Enables factory default settings for brightness,
contrast, tint, color, and volume.
PIP menu
Selects picture-in-picture application.
Power on option
Selects the video input to be displayed upon
power-up after a power interruption.
The factory default setting is CVB1.
VGA timing
Display information of H frequency, V
frequency, pixel clock, and resolution
information.
Exit
Exit the OSD Menu and returns to standard
monitor display.
NOTE:
OSD Main Menu disappears from the display after 15
seconds if no selections or adjustments are made.
Front Panel Lock-out Feature
Push , , , , keys simultaneously to
lock or unlock front panel access.