Bosch ISC-SM-90 Скачать руководство пользователя страница 4

 

F.01U.326.909-02 

© 2016 Bosch Security Systems, Inc. 

4.

 

Wire the connection cables to the terminal (Fig. 1, item B) as shown in 
diagram (Fig. 6). 

5.

 

Secure the cable to a cable anchor (Fig. 1, items C) with a cable tie (pro-
vided). 

6.

 

Connect the accessories and program the detector. 

7.

 

Remove the pre-formed cable access points as required to enable cable 
access through the skirt (Fig. 5). 

8.

 

Replace the cable access skirt. 

7.

 

Accessories 

All of the accessories (Fig. 7) have their own installation instructions, which 
are supplied with each accessory. These installation instructions should be 
followed for the correct installation and optimum performance from this 
seismic detector. For ordering information, see section 14. 

8.

 

Programming 

8.1.

 

Application setting (Fig. 1, item K) 

The specified operating radius applies to an attack with an oxygen lance, If 
attacked with a mechanical tool (e.g. a drill) the value may be as much as 
three times higher. The specified operating radius is a guideline which is 
heavily influenced by the characteristics of the material and the type of con-
struction.  
Select the material type for the protected space and the required detection 
radius by selecting the DIP switch options as follows: 

Operating 
radius (r) 

 

 

 

Mode Fixed 

Fixed 

Fixed 

USER 

MODE

Steel 

--- 

2m 

1.5m 

1 / 1.5 / 2m

LWS 

--- 

--- 

--- 

1,. / 2m

Concrete 

4m 

--- 

--- 

2.5 / 4 / 5m 

There are 3 settings selectable via the DIP switch (Fig. 1, item K), to enable 
the USER MODE selectable settings, through the ISN-SMS-W7 SensTool PC 
Software, DIP switches 1 & 2 must be in the ON position to establish 
communications between the PC and the detector. 

8.2.

 

Sensitivity (Fig. 6 terminal 7) 

 

When this input is active, the sensitivity of the detector is reduced. 
The sensitivity input should only be applied under special circum-
stances, and only for short periods of time. Any reduction in sensi-
tivity must comply with applicable regulations such as VdS in Ger-
many. The factory setting is Active low. Active high is selectable 
through the ISN-SMS-W7 SensTool PC Software. 

Sensitivity is reduced to 12.5% of the original setting for the duration of the 
remote signal. A potential application is the prevention of alarm triggering 
where loud functional noises prevail. 

8.3.

 

Test input (Fig. 6, terminal 4) 

The ISN-GMX-S1 internal test transmitter (Fig. 1, item H) is activated by the 
application of a low signal into the test input terminal. If the detector is 
functioning correctly, the detector will trigger an alarm (trigger time <3 
seconds). 
The factory setting is Active low, Active high is selectable through the ISN-
SMS-W7 SensTool PC Software. 

 

Active low = 0 V applied to activate. 
Active high = 0 V removed to activate. 

9.

 

LED display 

The red LED (Fig. 1, item E) pulses during initialisation. In the event of an 
alarm, the LED illuminates for approximately 2.5 seconds. This LED is only 
visible when the cover of the detector is removed. 

10.

 

Commissioning 

1.

 

Apply the supply voltage. 
The LED (Fig. 1, item E) pulses for 10 seconds. 

2.

 

Leave the detector for a further 20 seconds. 
The detector is now operational. 

3.

 

Verify the correct radius and material type have been selected by the DIP 
switches or the ISN-SMS-W7 SensTool PC Software. 

If SensTool is not available, use a multimeter (Ri ≥ 20 kΩ) at terminal 1 (0 V) 
and at the test point (Fig. 1, item D) to monitor for the analogue integration 
signal: 

Quiescent level 

0 V 

Integration start 

1 V 

Alarm threshold (w/o load) 

3 V 

Check for interference using the SensTool > Analyse option. The Digital Filter 
option in the Settings tab may assist in reducing inherent interference. For 
additional information, please refer to the SensTool PC Software and the 
associated manual.

 

10.1.

 

Functional checks 

Functional checks can be performed as follows 

 

With the cover removed, scratch the metal case of the detector with a 
screw driver until the LED (Fig. 1, item E) confirms an alarm. 

 

Apply the required input to terminal 4 to activate the ISN-GMX-S1 
internal test transmitter, if provided. 

 

Simulate an attack on the protected space. 

 

Carefully replace the cover and secure it in place. 

11.

 

Service 

The function of the detector and its mounting should be checked at least once 
a year, as follows: 

 

Functionally test the detector as detailed in section 10.1. 

 

Verify the settings of the detector by the DIP switches or by the ISN-
SMS-W7 SensTool PC Software . 

 

Check the mounting of the detector to ensure that the detector is se-
curely attached. 

 

Check that there is a direct connection between the detector and the 
mounting surface. Paint, varnish, dirt, silicone or similar materials will 
impede the acoustics. 

Refer to local approvals for guidance on this matter. 

12.

 

Modular vaults 

The following principles must be strictly observed when using seismic detec-
tors on modular vaults made from steel or concrete. 

 

Thickness from 100 to 400mm 

 

Width up to 1000mm 

 

Length up to 6500mm 

Modules with detector arrangement

 

 

 

Corner joints between walls seamlessly 
welded 

Always 1 detector on doors

 

 

1.

 

One detector for a maximum of 5 wall modules. The detector must be 
mounted on the middle module. 

2.

 

In addition to being bolted together, all of the joints between the 
modules must be welded every 400 − 500mm with a 30 − 40mm seam. 

3.

 

Corner joints between wall modules must be seamlessly welded if the 
coverage area is to extend beyond the corners. 

4.

 

In the case of wall modules equipped with detectors, the immediately 
adjoining floor and/or ceiling modules can be included in the coverage 
area if the corresponding butt joints are seamlessly welded. 

5.

 

Where building vaults use modules of varying thickness, the butt joints 
must be seamlessly welded. 

6.

 

Avoid mounting detectors on modules to which guide rails for cassette 
transport lifts, ventilators or other mechanical equipment are attached. 

7.

 

Always equip modules which have a pay-in/withdrawal slot with a 
detector. The detector can monitor the adjacent modules. 

8.

 

All doors must be equipped with a detector. 

9.

 

Programming: 

 Application 

setting 

Max. 5 modules

Concrete: 4m 

Doors Steel: 

2m 

13.

 

Technical data 

Dimensions

89mm x 89mm x 23mm

Supply voltage (nom. 12 VDC)

Vcc = 8 to 16 V DC

Current consumption (8 to 16 VDC)

Ityp. = 2.5 to 3.5 mA

 

Alarm condition

Imax. = 5 mA 

Alarm output, terminals 14+15:

 

Semiconductor relay

Opens on alarm + low voltage

 

Contact load 

30 V DC/100 mA, ohmic load 

 

Series resistance

<45 Ω 

1 2 3 4 5 1 2 3 4 5  .  .  .  .

Содержание ISC-SM-90

Страница 1: ...F 01U 326 909 02 1 2016 Bosch Security Systems Inc ISC SM 90 Installation Guide en Seismic detector de Körperschallmelder es Detector sísmico sv Seismisk detektor 10 2016 1 2 3 4 5 6 ...

Страница 2: ...F 01U 326 909 02 2 2016 Bosch Security Systems Inc 7 ...

Страница 3: ...rill 3 x 3 2mm holes 6mm deep 2 holes for the detector and 1 hole for the ISN GMX S1 internal test transmitter Fig 1 item H 2 Remove the drilling template 3 Thread all holes to M4 4 Secure the detector and the test transmitter to the mounting surface 5 2 Installation on steel using the ISN GMX P0 mounting plate Use the weld symbol side of the ISN GMX P0 mounting plate Fig 2 to install the detector...

Страница 4: ...and material type have been selected by the DIP switches or the ISN SMS W7 SensTool PC Software If SensTool is not available use a multimeter Ri 20 kΩ at terminal 1 0 V and at the test point Fig 1 item D to monitor for the analogue integration signal Quiescent level 0 V Integration start 1 V Alarm threshold w o load 3 V Check for interference using the SensTool Analyse option The Digital Filter op...

Страница 5: ...s zu schützenden Bereichs Melder zu montieren Eine Erfassung von angrenzenden Flächen aus sollte nicht Bestandtteil einer umfassenden Schutzstrategie sein 4 1 Melderabstand Melder müssen so positioniert werden dass sie den gesamten zu überwachenden Bereich abdecken Der Abstand zwischen den Meldern wird als Melderabstand bezeichnet sd engl spacing distance Melderabstand sd Für eine vollständige Abd...

Страница 6: ...aren USER MODE Einstellungen über die ISN SMS W7 SensTool Software müssen die DIP Schalter 1 und 2 in der EIN Position sein um die Kommunikation zwischen dem PC und dem Melder herzustellen 8 2 Empfindlichkeit Abb 6 Klemme 7 Wenn dieser Eingang aktiv ist wird die Melderempfindlichkeit verringert Der Empfindlichkeitseingang darf nur unter bestimmtem Umständen angewendet werden und das nur für kurze ...

Страница 7: ... Montageplatte F 01U 003 366 ISN GMX S1 Interner Prüfsender F 01U 003 371 ISN GMX W0 Wand Deckeneinbaudose F 01U 003 372 ISN GMX B0 Bodeneinbaudose F 01U 003 365 ISN GMX P3S Schlossschutz F 01U 003 368 ISN GMX PZ Schlossschutz F 01U 003 370 ISN GMX P3S2 Schlossschutz F 01U 003 367 ISN GMX D7 Bohrschutzfolie F 01U 004 305 ISN SMS W7 SensTool PC Software F 01U 003 306 es 1 Declaración de conformidad...

Страница 8: ...GMX P0 Fig 4 para instalar el detector sobre superficies de hormigón Cuando se instala sobre hormigón el ISN GMX S1 no debe tener contacto alguno con la placa de montaje ISN GMX P0 Es funda mental utilizar el lado y los métodos de montaje correctos En la placa ISN GMX P0 se puede ver un símbolo de detector que indica la dirección del acceso de los cables al detector Tome nota de la orientación del...

Страница 9: ...dica detalladamente en el apartado 10 1 Verifique la configuración del detector con los interruptores DIP o con el software SensTool del ISN SMS W7 Compruebe el montaje del detector para asegurarse de que está fijado de forma segura Compruebe que haya una conexión directa entre el detector y la superfi cie de montaje Las pinturas los barnices la suciedad la silicona y otros materiales similares pu...

Страница 10: ...es avstånd sd spacing distance Inbördes avstånd mellan detektorer sd För att uppnå en fullständig täckning av det skyddade området bör följande formel användas för att fastställa det korrekta inbördes avståndet mellan de seismiska detektorerna Inbördes avstånd sd aktionsradie r x 2 x 0 75 Exempel Material Aktionsradie Inbördes avstånd Stål 2m 3m Betong 4m 6m 5 Installation 5 1 Direkt installation ...

Страница 11: ...nisation som jobbar för brandskydd och säkerhet i hemmet Standardinställningen är Aktiv Låg Aktiv Hög är valbar via programvaran SensTool ISN SMS W7 Känsligheten minskas med 12 5 jämfört med den ursprungliga inställningen för fjärrsignalens varaktighet En möjlig tillämpning är för att undvika att larmet löses ut på platser där det förekommer höga funktionsljud 8 3 Testingång fig 6 uttag 4 Den inte...

Страница 12: ... 16 VDC Ityp 2 5 till 3 5 mA Larmförhållande Imax 5 mA Larmutmatning uttagen 14 15 Halvledarrelä Öppen vid larm låg spänning Kontaktladdning 30 V DC 100 mA ohmisk last Seriemotstånd 45 Ω Fördröjningstid larm 2 5 sekunder Elektronisk larmutmatning uttagen 12 Öppen kollektor Larm 0 V DC Kortslutningsstyrka 16 V DC Uttag för sabotageövervakning 10 11 Mikrobrytare kåpa golv Öppnas vid sabotage Kontakt...

Отзывы: