Wiring
Refer to Terminal strip below for transmitter/receiver terminal locations. Use duct
pipes for outdoor wiring. Do not use aerial wiring.
!
Caution!
Only apply power after all electrical connections are completed and inspected.
Notice!
Tamper and EDC terminals should be connected to a 24-hour supervisory loop
Notice!
Power is to be provided by a UL Listed burglar alarm power supply or burglar alarm control
panel. In case of power failure, the power supply or control unit shall have a minimum of 4
hours of standby power.
Notice!
All wiring is to be in accordance with the National Electric Code, ANSI/NFPA 70
Notice!
This system should be tested at least once a week to ensure proper function.
Terminal strip overview
1
2
3
4
3
5
6
4
Figure 4.1: Terminal strip component overview
Callout
﹘
Description
Callout
﹘
Description
1
ー
Receiver
4
ー
Tamper
2
ー
Transmitter
5
ー
Alarm output
3
ー
Power (non-polarized)
6
ー
EDC output
4
4.1
Photobeam 5000
Wiring | en
13
Bosch Security Systems, Inc.
Installation and Operation Guide
2016.02 | 03 | F.01U.305.910
Содержание ISC-FPB1-W120QS
Страница 1: ...Photobeam 5000 ISC FPB1 W60QS ISC FPB1 W120QS ISC FPB1 W200QS en Installation and Operation Guide ...
Страница 2: ......
Страница 26: ......
Страница 27: ......