Figure 31. Remove Ground Lug
15. Remove threaded ground lug.
Figure 32. Attach Wires
16. Feed the L1 wire into the L1 terminal slot in
the wiring chamber.
17. Feed the L2 wire into the L2 terminal slot in
the wiring chamber.
Figure 33. Attach Safety Ground Wire
18. Attach safety ground wire through the slot on the
ground terminal. Hand-tighten grounding lug.
NOTE: See inside of wiring chamber cover for wiring
schematic.
19.
Tighten terminal screws to 1.2 Nm (10.62 in-lb).
Figure 34. Reinstall Strain Relief
20. Reinstall strain relief.