10
Power Xpress™ Dual Bollard Charge Station
Installation Guide
576414 Rev. A
230V Above Ground (Europe)
230V Single Phase
LINE (H)
230VAC
NEUTRAL (N)
EARTH
Figure 4. 230V Single Phase
WARNING: The EVSE is a single-phase
device. When connecting the line and
neutral wires, take care that the service
transformer secondary connection is
known, and the wires from the main
circuit breaker panel are correctly
connected and labeled. The following
service connections are primarily used in
Europe and Australia (sometimes known
as “TT Power Grid”). Please reference
the following diagram. The line, neutral,
and earth outputs on the illustration
correspond to the inputs on the EVSE.
WARNING: The line connection must
measure 230V RMS to neutral. Earth must
also be connected to the EVSE.