background image

 

 

 

 

 

 

 

GV2 Series Control Panels 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

EN 

Owner's Manual 

Supplement 

 

Содержание GV2 Series

Страница 1: ...GV2 Series Control Panels EN Owner s Manual Supplement ...

Страница 2: ...ccordance with ANSI SIA CP 01 2000 UL Listed and Classified control unit Model D9412GV2 D7412GV2 or D7212GV2 UL Listed and Classified keypad Model D1256 D1257 D1260 D1255 D1255R or D1255 RW UL Listed Local Bell The minimum firmware requirements for SIA CP 01 compliance are Control Panel Firmware Version D9412GV2 7 05 or later D7412GV2 7 05 or later D7212GV2 7 05 or later ...

Страница 3: ... Follows Scope 8 2 4 1 Description 8 2 4 2 Using Passcode Follows Scope 8 2 5 Passcode Controlled Menu 9 2 5 1 Description 9 2 5 2 Using Passcode Controlled Menus 9 2 6 Walk Tests 10 2 6 1 Description 10 2 6 2 Using Walk Test 10 2 7 Door Activated Custom Function 12 2 7 1 Description 12 2 7 2 Using Door Activated Custom Functions 12 2 8 Access Level Control 13 2 8 1 Description 13 2 8 2 Using ACCE...

Страница 4: ... 3 4 Exit Error 23 3 3 5 Master Arm No Exit Feature Unvacated Premises 24 3 3 6 Recent Closing 24 3 4 User Caused False Alarms Disarming the System 24 3 4 1 Entry Time Defaults 24 3 4 2 Passcode Disarms System Area 24 3 5 Arming and Disarming with Keyswitches 25 3 6 Alarm Transmission Sequence Alarm Abort 25 3 6 2 Abort Window 25 3 6 3 Passcode Acknowledges Alarm 25 3 6 4 Alarms Acknowledged withi...

Страница 5: ...s 2 1 Two Man Rule 2 1 1 Description The Two Man Rule adds an extra step to the disarming process by requiring two unique passcodes to disarm an area from the same keypad I have this feature I do not have this feature 2 1 2 Using the Two Man Rule 1 Ensure that the keypad shows idle armed text or Disarm Now 2 Enter a valid passcode with the authority to Passcode Disarm by pressing the passcode digi...

Страница 6: ...this feature 2 2 2 Using Early Ambush 1 Ensure that the keypad shows idle armed text or Disarm Now 2 Enter a valid passcode with the authority to Passcode Disarm by pressing the passcode digits followed by the ENTER key D1260 or ENT key D1255 3 Ensure that the keypad shows idle disarmed text 4 You can now search the area however you must enter the second passcode before the preset Early Ambush Tim...

Страница 7: ... is always on 2 3 2 Using Easy Exit Control Switching armed states from Master to Perimeter 1 Ensure that the keypad shows idle master armed text 2 Press the COMMAND key The keypad shows SYSTEM COMMAND 3 Press 3 to Perimeter Arm 4 The keypad display shows the Exit Delay countdown 5 Enter or exit from the premises Switching armed states from Perimeter to Master 1 Ensure that the keypad shows idle p...

Страница 8: ...ture 2 4 2 Using Passcode Follows Scope Arming from a keypad with Panel Wide scope and Passcode Follows Scope enabled 1 Ensure that the keypad shows idle disarmed text 2 Ensure that you have a valid passcode with the authority to Passcode Arm in all areas 3 Enter your passcode by pressing the passcode digits followed by the ENTER key D1260 or ENT key D1255 4 The keypad shows ARMING 12345678 to ind...

Страница 9: ...his feature 2 5 2 Using Passcode Controlled Menus On a D1255 Keypad with the Passcode Controlled Menu enabled 1 Press the ESC key The keypad shows ENTER PASSCODE 2 Enter your passcode by pressing the passcode digits followed by the ENT key The first menu item for which you have authority appears On a D1260 Keypad with the Passcode Controlled Menu enabled 1 Press the Menu soft key in the lower righ...

Страница 10: ...e Menu Function Name Point Types Tested Walk COMMAND 4 4 WALK TEST Visible Perimeter and Interior Fire COMMAND 5 8 FIRE TEST Fire and 24 hour Invisible Not applicable INVISIBLE TEST Invisible Perimeter and Interior I have this feature I do not have this feature 2 6 2 Using Walk Test On a D1255 Keypad 1 If you use the command sequence press the keys shown in the Command Sequence column of Table 1 f...

Страница 11: ...1PT MISSNG HW Missing 9 Activate the point s sensor and observe the appropriate state change 10 Press the NEXT key to advance to the next untested point within the scope of the keypad 11 Repeat steps 8 through 10 until all points are tested On a D1260 Keypad 1 If you use the command sequence press the keys indicated in the Command Sequence column of Table 1 on page 10 for the necessary walk test T...

Страница 12: ...unction 2 7 1 Description The D9412GV2 and D7412GV2 allow a custom function to be activated when user credentials are presented to a D9210B Door Controller Reader The custom function executes as if the user performed a function at the keypad that is associated with the door controller I have this feature I do not have this feature 2 7 2 Using Door Activated Custom Functions Executing the door s cu...

Страница 13: ...NU key to enter the function list then press NEXT repeatedly until you reach the CHANGE LEVEL CTL prompt Press ENT 4 ACCESS LEVEL CTL appears indicating that you are affecting the authority levels of cards or tokens and not passcodes Press ENT 5 ENTER LEVEL appears Enter the access authority level number and press ENT 6 If the access level is currently disabled LEVEL ENABLE appears If the access l...

Страница 14: ... 9 Door Control 2 9 1 Description The door control function has three sub functions CYCLE DOOR UNLOCK DOOR SECURE DOOR CYCLE DOOR unlocks a door briefly to allow a person into an area UNLOCK DOOR unlocks a door to allow free access SECURE DOOR locks a door and prohibits access regardless of a user s authority level I have this feature I do not have this feature 2 9 2 Using Door Control On a D1255 ...

Страница 15: ...e Door Control soft key 4 All authorized door control function sub functions are listed Press the corresponding soft key to enter the sub function 2 9 3 Cycle Door 1 To unlock an access door briefly and allow a person into an area press ENT at the Cycle Door prompt The display shows CYCLE 1 2 3 4 5 6 7 8 if all doors are in a normal state and available If a door is not in a normal state the number...

Страница 16: ...e If a door is not in a normal state the number of the door is replaced with a symbol indicated in Table 3 on page 15 3 Enter the number of the door to unlock then press ENT This door unlocks and the display changes to reflect the new status of the doors For example to unlock Door 4 at the following prompt press 4 then press ENT UNLOCK DOOR 1 2 3 4 5 6 7 8 The display shows UNLOCK DOOR 1 2 3 U 5 6...

Страница 17: ... 7 8 The display shows SECURE DOOR 1 2 3 4 X 6 7 8 This indicates that all doors are in a normal state except for Door 5 which is secured 4 Press ESC to leave this sub function or enter another door number to unlock Each of these sub functions acts as a toggle switch To return a door to its normal state follow the same procedure used to change its state For example if Door 3 is secured to return i...

Страница 18: ...ction list in place of steps 2 and 3 to start this function 1 Press the MENU key to enter the function list 2 Press NEXT repeatedly until you reach the DEL USER prompt 3 Press ENT 4 The display shows DEL USER Enter the user number and press ENT 5 USER or user text such as the name of the user if this feature was programmed into your system by your security company appears allowing for confirmation...

Страница 19: ...6 You can also use the function list in place of steps 2 and 3 to start this function 1 Press the MENU key to enter the function list 2 Press NEXT until you reach the ADD CHNG USER prompt 3 Press ENT 4 The display shows ENTER USER Enter the user number and press ENT 5 The display shows USER or user text such as the name of the user if this feature was programmed into your system by your security c...

Страница 20: ...this area and press ENT Record this information 12 VALID AREA 2 appears Enter the information necessary for the areas in the scope of the keypad by following steps 10 and 11 for each area up to 8 areas 13 LEVEL ADDED or LEVEL CHANGED appears when all area assignments are made Press ENT At the end of each function press ESC to return to the ENTER USER prompt Press ESC again to return to idle text S...

Страница 21: ...ER ID 1 At the SUB USER ID prompt press ENT 2 SUB USER appears Enter 1 2 or 3 for the desired Sub User and press ENT 3 PRESENT CARD appears Present the card or token at the reader and wait for the tone 4 After the tone sounds the display shows CARD ADDED or CARD CHANGED if the Sub User number already existed ...

Страница 22: ...7 05 or later D7212GV2 7 05 or later 3 2 False Alarm Reduction Features False alarms are such an issue that the local authorities in some jurisdictions no longer respond to alarms The Security Industry Association SIA has developed a Control Panel False Alarm Reduction Standard that details design features for security control panels and their associated arming and disarming devices to reduce the ...

Страница 23: ...tire system During the last 10 sec of Exit Delay the control panel s Alarm Bell output pulses on and off for the last 10 sec of Exit Delay 3 3 3 Exit Time Restart The SIA standard requires that the control have an option that restarts Exit Delay if a user follows these steps 1 Starts Exit Delay arms the system 2 Exits and closes an Exit Delay zone 3 Returns through an Exit Delay zone 4 The control...

Страница 24: ...control panel creates an alarm recent closing event If the user armed with a passcode the user number is included in the recent closing report Recent Closing events are not created for Fire Alarm events 3 4 User Caused False Alarms Disarming the System 3 4 1 Entry Time Defaults The SIA standard requires an Entry Time of between 30 sec and 4 min The required default is 30 sec If the system is not d...

Страница 25: ... and abort the alarm transmission The following sections explain how this feature works 3 6 1 Abort Window The Abort Window is the time the end user has to acknowledge an alarm and effectively abort the control panel s alarm response The Abort Window is programmable The minimum duration is 15 sec The maximum duration is 45 sec The default is 30 sec In accordance with UL standards the SIA standard ...

Страница 26: ...ds the appropriate alarm reports 3 7 Cancel Report and Cancel Window If a user acknowledges an alarm after the Abort Window expires but before Bell Time expires the control panel sends a Cancel Report The Cancel Window starts when the alarm is sent and stops when the Alarm Bell timer expires or a user acknowledges an alarm 3 8 Duress Alarm This feature allows any passcode with the Send Duress perm...

Страница 27: ...GV2 Series Control Panels Owner s Manual Supplement Bosch Security Systems Inc 2 07 F01U063791 01 27 Notes ...

Страница 28: ... 2007 Bosch Security Systems F01U063791 01 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...

Отзывы: