6 720 816 815 (2016/10)
Greentherm 9800 SE 160/199 | SEC 199
44 | Operating Instructions
▶ Use the symbols
or
to set between 10 seconds
and 1 hour.
▶ Touch the symbol
after reaching the desired value.
The time is defined, the brightness value must now be
programmed.
▶ Use the symbols
or
to set the brightness of the
display when in period of inactivity.
▶ Touch the symbol
after reaching the desired
brightness.
AB Region Selection
▶ Touch the symbol
.
Display shows following menu.
–
Europe
–
USA
–
Canada
6.5.4 “AU” - Authentication
▶ See section 6.6.
6.6
Service menu - AU (Authentication)
Accessing the AU Authentication menu
▶ Touch the symbol
.
Display shows
P4 Information
.
▶ Touch symbols
or
to select
AU Authentication
menu.
▶ Touch the symbol
.
Display shows authentication menu (password input).
▶ Select the password (1886).
Authentication completed.
▶ Touch the symbol
.
Access to
installer exclusive menus
.
•
P0 - Min. Power
•
P1 - Maximum Power
•
P2 - Minimum Power
•
P7 - Gas Type (LPG, NG)
•
PC - Cascading
(activation / deactivation)
•
PE - Appliance Type
•
PF - Bypass (On / Off)
•
PA - Actuator Calibration
•
U1 - L1 Auto Adjustment
•
U2 - L2 Auto Adjustment
6.7
Factory default settings
Restore factory values for P1 Max. Power
▶ Access to menu
P1 Max. Power
.
▶ Touch symbols
or
to select
Reset Parameters
.
▶ Touch the symbol
.
The display blinks to confirm change.
▶ Touch the symbol
.
The factory default values for
P1
are restored.
Restore factory values for P2 Max. Power
▶ Access to menu
P2 Min. Power
.
▶ Touch symbols
or
to select
Reset Parameters
.
▶ Touch the symbol
.
The display blinks to confirm change.
▶ Touch the symbol
.
The factory default values for
P2
are restored.
6.8
Water actuators calibration
6.8.1 MF main valve auto calibration
▶ Open one hot water tap.
▶ Access menu
PA
.
▶ Touch symbol
OK
.
▶ Touch symbols
or
to select
MF main valve
.
▶ Touch symbol
OK
.
The appliance will start the auto calibration of main valve.
▶ Touch the symbol
to return to main menu.
DANGER:
▶ Only for trained personnel.
Water actuators calibration must only be
done when main water valve or bypass valve
is replaced.
The water actuators calibration process
takes several minutes.
▶ Do not interfere with the appliance.
Only possible after access Authentication
menu (
Water flow will shut-off.
▶ Wait until indication of calibration
completed appears on the screen.