English |
39
Cause:
The surfaces used for calibration were not exactly aligned on a horizontal or ver-
tical level
Corrective measure:
Repeat the calibration on a horizontal or vertical surface and check
the surfaces beforehand, if necessary, using a spirit level
Cause:
The measuring tool was moved or tilted when pressing the button
Corrective measure:
Repeat the calibration and hold the measuring tool still on the sur-
face while pressing the button
Measurement Result
Measurement result unreliable
Cause:
Target surface is not reflecting clearly (e.g. water, glass)
Corrective measure:
Cover the target surface
Cause:
Laser beam output
(19)
or reception lens
(18)
is concealed
Corrective measure:
Always keep the laser beam output
(19)
and the reception
lens
(18)
clear
Measurement result implausible
Cause:
Obstacle in the course of the laser beam
Corrective measure:
Ensure that the laser point is fully on the target surface
Cause:
Incorrect reference level set
Corrective measure:
Select the reference level appropriate to the measurement
Bluetooth®
Bluetooth®
cannot be activated
Cause:
Non-rechargeable batteries or rechargeable batteries are too weak
Corrective measure:
Replace the non-rechargeable batteries or charge the rechargeable
battery of the measuring tool
No
Bluetooth®
connection
No
Bluetooth®
connection, "ERROR" indicator in the display
Cause:
Disruption of the
Bluetooth®
connection
Bosch Power Tools
1 609 92A 7E1 | (14.12.2021)
Содержание GLM 100-25 C
Страница 76: ...76 繁體中文 雷射標靶 24 2 607 001 391 雷射辨識鏡 紅色 25 1 608 M00 05B 1 609 92A 7E1 14 12 2021 Bosch Power Tools ...
Страница 115: ...한국어 115 삼각대 BT 150 26 0 601 096 B00 Bosch Power Tools 1 609 92A 7E1 14 12 2021 ...
Страница 232: ...232 Tiếng Việt Giá chân BT 150 26 0 601 096 B00 1 609 92A 7E1 14 12 2021 Bosch Power Tools ...