![Bosch GLL 5-50 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/bosch/gll-5-50/gll-5-50_original-instructions-manual_45828007.webp)
English |
7
Bosch Power Tools
1 609 92A 0MH | (16.5.14)
Technical Data
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery lid
3
, press on the latch
2
and remove the
battery lid. Insert the batteries. When inserting, pay attention
to the correct polarity according to the representation on the
inside of the battery compartment.
If the battery warning
16
flashes, the batteries have to be
replaced.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods.
When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
Using the Rotating Platform (see figure A)
Place the measuring tool on the tool mount of the rotating
platform
12
so that the locking grooves
13
of the rotating
platform fit between the corresponding grooves
6
on the bot-
tom of the measuring tool. Turn the measuring tool clockwise
to lock it on the rotating platform.
Extend the legs of the rotating platform using the height ad-
justment screws
10
. Roughly align the rotating platform using
the vial
8
.
Operation
Initial Operation
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature.
As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
Avoid heavy impact or falling of the measuring tool.
Af-
ter heavy exterior impact on the measuring tool, an accura-
cy check should always be carried out before continuing to
work (see “Levelling Accuracy”).
Switch the measuring tool off during transport.
When
switching off, the levelling unit, which can be damaged in
case of intense movement, is locked.
Switching On and Off
To
switch on
the measuring tool, slide the on/off switch
7
to
the
“
On”
position (for working without automatic levelling)
or to the
“
On”
position (for working with automatic level-
ling). The power indicator
16
lights up and the measuring tool
immediately sends a horizontal laser line out of the front exit
opening
1
.
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
To
switch off
the measuring tool, slide the on/off switch
7
to
the
“Off”
position. The power indicator
16
goes out. The pen-
dulum unit is locked when the tool is switched off.
When exceeding the maximum permitted operating tempera-
ture of 45 °C, the measuring tool switches off to protect the
laser diode. After cooling down, the measuring tool is ready
for operation and can be switched on again.
Line laser
GLL 5-50
Article number
3 601 K63 F..
Working range
1)
– Standard laser lines
– with pulse function
– with laser receiver
– Plumb point
m
m
m
m
15
10
5–50
5
Levelling accuracy of laser
lines
mm/m
±0.2
Self-levelling range, typically
°
±3
Levelling duration, typically
s
<4
Operating temperature
°C
–10 ... +45
Storage temperature
°C
–20 ... +70
Relative air humidity, max.
%
90
Laser class
2
Laser type
nm
mW
630–650
<1
C
6
1
Shortest pulse duration
ms
1.25
Tripod Mount
2)
"
5/8
Batteries
4 x 1.5 V LR06 (AA)
Operating time, approx.
– with 1 laser line
– with 2 laser lines
– with 3 laser lines
– with 5 laser lines
h
h
h
h
40
24
17
10
Weight according to
EPTA-Procedure 01/2003
kg
0.5
Dimensions
(length x width x height)
– without rotating platform
– with rotating platform
mm
mm
122 x 83 x 129
Ø 151 x 203
Degree of protection (exclud-
ing battery compartment)
IP 54*
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
2) only available in combination with the rotating platform
* dust and splash proof
The measuring tool can be clearly identified with the serial number
4
on
the type plate.
OBJ_BUCH-2195-001.book Page 7 Friday, May 16, 2014 2:18 PM