Technical Data
Router/contour router
GOF 1600 CE
GKF 1600 CE
Article number
3 601 F24 0..
3 601 F24 0..
Rated power input
W
1600
1600
No-load speed
min
−1
10000–25000
10000–25000
Speed preselection
●
●
Constant electronic control
●
●
Connection for dust extraction
●
●
Compatible collets
mm
inches
8–12
¼–½
8–12
¼–½
Router cage stroke
mm
76
–
Weight according to EPTA‑Procedure 01:2014
kg
5.8
4.3
Protection class
/II
/II
The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.
Noise/Vibration Information
Noise emission values determined according to
EN 62841-2-17
.
Typically the A-weighted noise level of the power tool are:
86
dB(A); sound power level
97
dB(A). Uncertainty K =
3
dB.
Wear hearing protection!
GOF 1600 CE:
Vibration total values a
h
(triax vector sum)
and uncertainty K determined according to
EN 62841-2-17
:
a
h
=
5.5
m/s
2
, K =
1.5
m/s
2
.
GOF 1600 CE:
Vibration total values a
h
(triax vector sum)
and uncertainty K determined according to
EN 62841-2-17
:
a
h
=
6
m/s
2
, K =
1.5
m/s
2
.
The vibration level and noise emission value given in these
instructions have been measured in accordance with a
standardised measuring procedure and may be used to com-
pare power tools. They may also be used for a preliminary
estimation of vibration and noise emissions.
The stated vibration level and noise emission value repres-
ent the main applications of the power tool. However, if the
power tool is used for other applications, with different ap-
plication tools or is poorly maintained, the vibration level
and noise emission value may differ. This may significantly
increase the vibration and noise emissions over the total
working period.
To estimate vibration and noise emissions accurately, the
times when the tool is switched off or when it is running but
not actually being used should also be taken into account.
This may significantly reduce vibration and noise emissions
over the total working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping their hands warm,
and organising workflows correctly.
Fitting
u
Pull the plug out of the socket before carrying out any
work on the power tool.
Inserting the routing motor into the plunge base/
non-plunge base (see figures A–B)
Open the clamping lever for the plunge base/non-plunge
base
(22)
.
Push the routing motor all the way into the plunge base/non-
plunge base.
When using the non-plunge base
(3)
, press the clamping
lever
(25)
and slide the routing motor
(1)
up or down to the
required position in the non-plunge base
(3)
, until it, with
the clamping lever
(25)
released, engages in one of the
three notches
(26)
.
Close the clamping lever of the plunge base/non-plunge
base
(22)
.
Set the required routing depth (see "Setting the routing
depth", page 23).
Separating the routing motor from the plunge unit/non-
plunge base (see figure C)
Open the clamping lever for the plunge base/non-plunge
base
(22)
.
Bosch Power Tools
1 609 92A 57S | (16.04.2021)
Содержание GKF 1600 CE Professional
Страница 3: ... 3 GOF 1600 CE GKF 1600 CE 1 2 3 4 4 Bosch Power Tools 1 609 92A 57S 16 04 2021 ...
Страница 5: ... 5 GKF 1600 CE 19 20 24 21 22 25 23 Bosch Power Tools 1 609 92A 57S 16 04 2021 ...
Страница 9: ... 9 2 54 55 14 14 55 54 3 3 24 56 57 58 58 59 R S T U Bosch Power Tools 1 609 92A 57S 16 04 2021 ...
Страница 276: ...276 1 609 92A 57S 16 04 2021 Bosch Power Tools ...