1 1 0 |
Bosch Geothermal Heat Pumps
Bosch Thermotechnology Corp.
Data subject to change
Applications Manual
17.4 Emerson Comfort Alert™ Diagnostic
Module
Many geothermal heat pumps utilize a self-diagnostic
device to assist in troubleshooting. The Comfort Alert
diagnostics module (CADM) is a breakthrough innovation
for troubleshooting heat pump and air conditioning
system failures (Fig. 131). The module installs easily in
the electrical box near the compressor contactor. By
monitoring and analyzing data from the Copeland Scroll
® compressor and the thermostat demand, the module
can accurately detect the cause of electrical and system
related failures without any sensors. A ashing LED
indicator communicates the ALERT code and guides the
service technician more quickly and accurately to the root
cause of a problem.
Fig. 131
This module does not provide safety protection!
The Comfort Alert module is a monitoring device
and cannot shut down the compressor directly.
When an abnormal system condition occurs, the Comfort
Alert module displays the appropriate ALERT and/or
TRIP LED. The yellow ALERT LED will ash a number of
times consecutively, pause and then repeat the process.
To identify a Flash Code number, count the number of
consecutive ashes. Every time the module powers up, the
last ALERT Flash Code that occurred prior to shut down is
displayed for one minute.
Содержание Geothermal Heat Pumps
Страница 1: ...Bosch Geothermal Heat Pumps For Residential Applications Applications Manual ...
Страница 2: ...2 Bosch Geothermal Heat Pumps Bosch Thermotechnology Corp Data subject to change Applications Manual ...
Страница 126: ...126 Bosch Geothermal Heat Pumps Bosch Thermotechnology Corp Data subject to change Applications Manual ...
Страница 127: ...Applications Manual Bosch Geothermal Heat Pumps 127 Bosch Thermotechnology Corp Data subject to change ...