55
INSTALLER SETTINGS menu settings (for installers only)
6 720 617 763 (2008/09)
8.1.7 INSTALLER SETTINGS: System info
8.1.8 INSTALLER SETTINGS: Floor drying
System info menu structure
Example
Setting range
Personal
setting
Description
starts on page
Installation date
10/22/2008
(activated on
commission-
ing)
– –
Boiler part number
7 777 777 777
(data from
boiler)
– –
Boiler date of manufacture
06/27/2008
(data from
boiler)
– –
Controller part number and
model
7 777 777 777
FW 100 (fixed
factory set-
ting)
– –
Controller date of manufacture
06/27/2008
(fixed factory
setting)
– –
Controller software version
JF11.12 (fixed
factory set-
ting)
– –
Tab. 19
Floor drying menu structure
Default
setting
Setting range
Personal
setting
Description
starts on page
Cancel floor drying
1)
No
No | Yes
Maximum CH flow temperature 25 °C
25 °C ... 60 °C
°C
Maintain max CH flow temp for 1 days
1 day ... 20 days
d
Total floor drying time
calculated
calculated... 60 d(not less than
“Maintain max CH flow temp for”)
–
Start date
– – . – – . –
– – –
Today ... 31/12/2099
(in increments of one day/month/
year)
Start time
– – : – –
00:00 ... 23:59
(in increments of one hour/
minute)
Tab. 20
1) Only available if “Floor drying” is active.